honeywell CVE Vulnerabilities & Metrics

Focus on honeywell vulnerabilities and metrics.

Last updated: 08 Mar 2025, 23:25 UTC

About honeywell Security Exposure

This page consolidates all known Common Vulnerabilities and Exposures (CVEs) associated with honeywell. We track both calendar-based metrics (using fixed periods) and rolling metrics (using gliding windows) to give you a comprehensive view of security trends and risk evolution. Use these insights to assess risk and plan your patching strategy.

For a broader perspective on cybersecurity threats, explore the comprehensive list of CVEs by vendor and product. Stay updated on critical vulnerabilities affecting major software and hardware providers.

Global CVE Overview

Total honeywell CVEs: 61
Earliest CVE date: 31 May 2007, 00:30 UTC
Latest CVE date: 31 Jan 2024, 18:15 UTC

Latest CVE reference: CVE-2023-5390

Rolling Stats

30-day Count (Rolling): 0
365-day Count (Rolling): 0

Calendar-based Variation

Calendar-based Variation compares a fixed calendar period (e.g., this month versus the same month last year), while Rolling Growth Rate uses a continuous window (e.g., last 30 days versus the previous 30 days) to capture trends independent of calendar boundaries.

Variations & Growth

Month Variation (Calendar): 0%
Year Variation (Calendar): -100.0%

Month Growth Rate (30-day Rolling): 0.0%
Year Growth Rate (365-day Rolling): -100.0%

Monthly CVE Trends (current vs previous Year)

Annual CVE Trends (Last 20 Years)

Critical honeywell CVEs (CVSS ≥ 9) Over 20 Years

CVSS Stats

Average CVSS: 4.55

Max CVSS: 10.0

Critical CVEs (≥9): 7

CVSS Range vs. Count

Range Count
0.0-3.9 22
4.0-6.9 24
7.0-8.9 14
9.0-10.0 7

CVSS Distribution Chart

Top 5 Highest CVSS honeywell CVEs

These are the five CVEs with the highest CVSS scores for honeywell, sorted by severity first and recency.

All CVEs for honeywell

CVE-2023-5390 honeywell vulnerability CVSS: 0 31 Jan 2024, 18:15 UTC

An attacker could potentially exploit this vulnerability, leading to files being read from the Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC. This exploit could be used to read files from the controller that may expose limited information from the device. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning.

CVE-2023-5389 honeywell vulnerability CVSS: 0 30 Jan 2024, 20:15 UTC

An attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning. 

CVE-2023-6179 honeywell vulnerability CVSS: 0 17 Nov 2023, 17:15 UTC

Honeywell ProWatch, 4.5, including all Service Pack versions, contain a Vulnerability in Application Server's executable folder(s). A(n) attacker could potentially exploit this vulnerability, leading to a standard user to have arbitrary system code execution. Honeywell recommends updating to the most recent version of this product, service or offering (Pro-watch 6.0.2, 6.0, 5.5.2,5.0.5).

CVE-2023-3243 honeywell vulnerability CVSS: 0 28 Jun 2023, 21:15 UTC

** UNSUPPORTED WHEN ASSIGNED ** [An attacker can capture an authenticating hash and utilize it to create new sessions. The hash is also a poorly salted MD5 hash, which could result in a successful brute force password attack. Impacted product is BCM-WEB version 3.3.X. Recommended fix: Upgrade to a supported product such as Alerton ACM.] Out of an abundance of caution, this CVE ID is being assigned to better serve our customers and ensure all who are still running this product understand that the product is end of life and should be removed or upgraded. 

CVE-2022-4240 honeywell vulnerability CVSS: 0 30 May 2023, 17:15 UTC

Missing Authentication for Critical Function vulnerability in Honeywell OneWireless allows Authentication Bypass. This issue affects OneWireless version 322.1

CVE-2022-46361 honeywell vulnerability CVSS: 0 30 May 2023, 17:15 UTC

An attacker having physical access to WDM can plug USB device to gain access and execute unwanted commands. A malicious user could enter a system command along with a backup configuration, which could result in the execution of unwanted commands. This issue affects OneWireless all versions up to 322.1 and fixed in version 322.2.

CVE-2022-43485 honeywell vulnerability CVSS: 0 30 May 2023, 17:15 UTC

Use of Insufficiently Random Values in Honeywell OneWireless. This vulnerability may allow attacker to manipulate claims in client's JWT token. This issue affects OneWireless version 322.1

CVE-2021-38399 honeywell vulnerability CVSS: 0 28 Oct 2022, 02:15 UTC

Honeywell Experion PKS C200, C200E, C300, and ACE controllers are vulnerable to relative path traversal, which may allow an attacker access to unauthorized files and directories.

CVE-2021-38397 honeywell vulnerability CVSS: 0 28 Oct 2022, 02:15 UTC

Honeywell Experion PKS C200, C200E, C300, and ACE controllers are vulnerable to unrestricted file uploads, which may allow an attacker to remotely execute arbitrary code and cause a denial-of-service condition.

CVE-2021-38395 honeywell vulnerability CVSS: 0 28 Oct 2022, 02:15 UTC

Honeywell Experion PKS C200, C200E, C300, and ACE controllers are vulnerable to improper neutralization of special elements in output, which may allow an attacker to remotely execute arbitrary code and cause a denial-of-service condition.

CVE-2022-2333 honeywell vulnerability CVSS: 0 16 Sep 2022, 22:15 UTC

If an attacker manages to trick a valid user into loading a malicious DLL, the attacker may be able to achieve code execution in Honeywell SoftMaster version 4.51 application’s context and permissions.

CVE-2022-2332 honeywell vulnerability CVSS: 0 16 Sep 2022, 22:15 UTC

A local unprivileged attacker may escalate to administrator privileges in Honeywell SoftMaster version 4.51, due to insecure permission assignment.

CVE-2022-30312 honeywell vulnerability CVSS: 0 07 Sep 2022, 18:15 UTC

The Trend Controls IC protocol through 2022-05-06 allows Cleartext Transmission of Sensitive Information. According to FSCT-2022-0050, there is a Trend Controls Inter-Controller (IC) protocol cleartext transmission of credentials issue. The affected components are characterized as: Inter-Controller (IC) protocol (57612/UDP). The potential impact is: Compromise of credentials. Several Trend Controls building automation controllers utilize the Inter-Controller (IC) protocol in for information exchange and automation purposes. This protocol offers authentication in the form of a 4-digit PIN in order to protect access to sensitive operations like strategy uploads and downloads as well as optional 0-30 character username and password protection for web page access protection. Both the PIN and usernames and passwords are transmitted in cleartext, allowing an attacker with passive interception capabilities to obtain these credentials. Credentials are transmitted in cleartext. An attacker who obtains Trend IC credentials can carry out sensitive engineering actions such as manipulating controller strategy or configuration settings. If the credentials in question are (re)used for other applications, their compromise could potentially facilitate lateral movement.

CVE-2022-30318 honeywell vulnerability CVSS: 0 31 Aug 2022, 16:15 UTC

Honeywell ControlEdge through R151.1 uses Hard-coded Credentials. According to FSCT-2022-0056, there is a Honeywell ControlEdge hardcoded credentials issue. The affected components are characterized as: SSH. The potential impact is: Remote code execution, manipulate configuration, denial of service. The Honeywell ControlEdge PLC and RTU product line exposes an SSH service on port 22/TCP. Login as root to this service is permitted and credentials for the root user are hardcoded without automatically changing them upon first commissioning. The credentials for the SSH service are hardcoded in the firmware. The credentials grant an attacker access to a root shell on the PLC/RTU, allowing for remote code execution, configuration manipulation and denial of service.

CVE-2022-30317 honeywell vulnerability CVSS: 0 31 Aug 2022, 16:15 UTC

Honeywell Experion LX through 2022-05-06 has Missing Authentication for a Critical Function. According to FSCT-2022-0055, there is a Honeywell Experion LX Control Data Access (CDA) EpicMo protocol with unauthenticated functionality issue. The affected components are characterized as: Honeywell Control Data Access (CDA) EpicMo (55565/TCP). The potential impact is: Firmware manipulation, Denial of service. The Honeywell Experion LX Distributed Control System (DCS) utilizes the Control Data Access (CDA) EpicMo protocol (55565/TCP) for device diagnostics and maintenance purposes. This protocol does not have any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality. There is no authentication functionality on the protocol in question. An attacker capable of invoking the protocols' functionalities could issue firmware download commands potentially allowing for firmware manipulation and reboot devices causing denial of service.

CVE-2022-30320 honeywell vulnerability CVSS: 0 28 Jul 2022, 16:15 UTC

Saia Burgess Controls (SBC) PCD through 2022-05-06 uses a Broken or Risky Cryptographic Algorithm. According to FSCT-2022-0063, there is a Saia Burgess Controls (SBC) PCD S-Bus weak credential hashing scheme issue. The affected components are characterized as: S-Bus (5050/UDP) authentication. The potential impact is: Authentication bypass. The Saia Burgess Controls (SBC) PCD controllers utilize the S-Bus protocol (5050/UDP) for a variety of engineering purposes. It is possible to configure a password in order to restrict access to sensitive engineering functionality. Authentication is done by using the S-Bus 'write byte' message to a specific address and supplying a hashed version of the password. The hashing algorithm used is based on CRC-16 and as such not cryptographically secure. An insecure hashing algorithm is used. An attacker capable of passively observing traffic can intercept the hashed credentials and trivially find collisions allowing for authentication without having to bruteforce a keyspace defined by the actual strength of the password. This allows the attacker access to sensitive engineering functionality such as uploading/downloading control logic and manipulating controller configuration.

CVE-2022-30319 honeywell vulnerability CVSS: 0 28 Jul 2022, 16:15 UTC

Saia Burgess Controls (SBC) PCD through 2022-05-06 allows Authentication bypass. According to FSCT-2022-0062, there is a Saia Burgess Controls (SBC) PCD S-Bus authentication bypass issue. The affected components are characterized as: S-Bus (5050/UDP) authentication. The potential impact is: Authentication bypass. The Saia Burgess Controls (SBC) PCD controllers utilize the S-Bus protocol (5050/UDP) for a variety of engineering purposes. It is possible to configure a password in order to restrict access to sensitive engineering functionality. Authentication functions on the basis of a MAC/IP whitelist with inactivity timeout to which an authenticated client's MAC/IP is stored. UDP traffic can be spoofed to bypass the whitelist-based access control. Since UDP is stateless, an attacker capable of passively observing traffic can spoof arbitrary messages using the MAC/IP of an authenticated client. This allows the attacker access to sensitive engineering functionality such as uploading/downloading control logic and manipulating controller configuration.

CVE-2022-30316 honeywell vulnerability CVSS: 0 28 Jul 2022, 16:15 UTC

Honeywell Experion PKS Safety Manager 5.02 has Insufficient Verification of Data Authenticity. According to FSCT-2022-0054, there is a Honeywell Experion PKS Safety Manager unauthenticated firmware update issue. The affected components are characterized as: Firmware update functionality. The potential impact is: Firmware manipulation. The Honeywell Experion PKS Safety Manager utilizes the DCOM-232/485 communication FTA serial interface and Enea POLO bootloader for firmware management purposes. An engineering workstation running the Safety Builder software communicates via serial or serial-over-ethernet link with the DCOM-232/485 interface. Firmware images were found to have no authentication (in the form of firmware signing) and only relied on insecure checksums for regular integrity checks. Firmware images are unsigned. An attacker with access to the serial interface (either through physical access, a compromised EWS or an exposed serial-to-ethernet gateway) can utilize hardcoded credentials (see FSCT-2022-0052) for the POLO bootloader to control the boot process and push malicious firmware images to the controller allowing for firmware manipulation, remote code execution and denial of service impacts. A mitigating factor is that in order for a firmware update to be initiated, the Safety Manager has to be rebooted which is typically done by means of physical controls on the Safety Manager itself. As such, an attacker would have to either lay dormant until a legitimate reboot occurs or possibly attempt to force a reboot through a secondary vulnerability.

CVE-2022-30315 honeywell vulnerability CVSS: 0 28 Jul 2022, 16:15 UTC

Honeywell Experion PKS Safety Manager (SM and FSC) through 2022-05-06 has Insufficient Verification of Data Authenticity. According to FSCT-2022-0053, there is a Honeywell Experion PKS Safety Manager insufficient logic security controls issue. The affected components are characterized as: Honeywell FSC runtime (FSC-CPU, QPP), Honeywell Safety Builder. The potential impact is: Remote Code Execution, Denial of Service. The Honeywell Experion PKS Safety Manager family of safety controllers utilize the unauthenticated Safety Builder protocol (FSCT-2022-0051) for engineering purposes, including downloading projects and control logic to the controller. Control logic is downloaded to the controller on a block-by-block basis. The logic that is downloaded consists of FLD code compiled to native machine code for the CPU module (which applies to both the Safety Manager and FSC families). Since this logic does not seem to be cryptographically authenticated, it allows an attacker capable of triggering a logic download to execute arbitrary machine code on the controller's CPU module in the context of the runtime. While the researchers could not verify this in detail, the researchers believe that the microprocessor underpinning the FSC and Safety Manager CPU modules is incapable of offering memory protection or privilege separation capabilities which would give an attacker full control of the CPU module. There is no authentication on control logic downloaded to the controller. Memory protection and privilege separation capabilities for the runtime are possibly lacking. The researchers confirmed the issues in question on Safety Manager R145.1 and R152.2 but suspect the issue affects all FSC and SM controllers and associated Safety Builder versions regardless of software or firmware revision. An attacker who can communicate with a Safety Manager controller via the Safety Builder protocol can execute arbitrary code without restrictions on the CPU module, allowing for covert manipulation of control operations and implanting capabilities similar to the TRITON malware (MITRE ATT&CK software ID S1009). A mitigating factor with regards to some, but not all, of the above functionality is that these require the Safety Manager physical keyswitch to be in the right position.

CVE-2022-30314 honeywell vulnerability CVSS: 0 28 Jul 2022, 16:15 UTC

Honeywell Experion PKS Safety Manager 5.02 uses Hard-coded Credentials. According to FSCT-2022-0052, there is a Honeywell Experion PKS Safety Manager hardcoded credentials issue. The affected components are characterized as: POLO bootloader. The potential impact is: Manipulate firmware. The Honeywell Experion PKS Safety Manager utilizes the DCOM-232/485 serial interface for firmware management purposes. When booting, the Safety Manager exposes the Enea POLO bootloader via this interface. Access to the boot configuration is controlled by means of credentials hardcoded in the Safety Manager firmware. The credentials for the bootloader are hardcoded in the firmware. An attacker with access to the serial interface (either through physical access, a compromised EWS or an exposed serial-to-ethernet gateway) can utilize these credentials to control the boot process and manipulate the unauthenticated firmware image (see FSCT-2022-0054).

CVE-2022-30313 honeywell vulnerability CVSS: 0 28 Jul 2022, 16:15 UTC

Honeywell Experion PKS Safety Manager through 2022-05-06 has Missing Authentication for a Critical Function. According to FSCT-2022-0051, there is a Honeywell Experion PKS Safety Manager multiple proprietary protocols with unauthenticated functionality issue. The affected components are characterized as: Honeywell Experion TCP (51000/TCP), Safety Builder (51010/TCP). The potential impact is: Manipulate controller state, Manipulate controller configuration, Manipulate controller logic, Manipulate controller files, Manipulate IO. The Honeywell Experion PKS Distributed Control System (DCS) Safety Manager utilizes several proprietary protocols for a wide variety of functionality, including process data acquisition, controller steering and configuration management. These protocols include: Experion TCP (51000/TCP) and Safety Builder (51010/TCP). None of these protocols have any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality. There is no authentication functionality on the protocols in question. An attacker capable of invoking the protocols' functionalities could achieve a wide range of adverse impacts, including (but not limited to), the following: for Experion TCP (51000/TCP): Issue IO manipulation commands, Issue file read/write commands; and for Safety Builder (51010/TCP): Issue controller start/stop commands, Issue logic download/upload commands, Issue file read commands, Issue system time change commands. A mitigating factor with regards to some, but not all, of the above functionality is that these require the Safety Manager physical keyswitch to be in the right position.

CVE-2022-30245 honeywell vulnerability CVSS: 0 15 Jul 2022, 12:15 UTC

Honeywell Alerton Compass Software 1.6.5 allows unauthenticated configuration changes from remote users. This enables configuration data to be stored on the controller and then implemented. A user with malicious intent can send a crafted packet to change the controller configuration without the knowledge of other users, altering the controller's function capabilities. The changed configuration is not updated in the User Interface, which creates an inconsistency between the configuration display and the actual configuration on the controller. After the configuration change, remediation requires reverting to the correct configuration, requiring either physical or remote access depending on the configuration that was altered.

CVE-2022-1261 honeywell vulnerability CVSS: 9.0 26 May 2022, 17:15 UTC

Matrikon, a subsidary of Honeywell Matrikon OPC Server (all versions) is vulnerable to a condition where a low privileged user allowed to connect to the OPC server to use the functions of the IPersisFile to execute operating system processes with system-level privileges.

CVE-2021-39364 honeywell vulnerability CVSS: 5.0 24 Feb 2022, 22:15 UTC

Honeywell HDZP252DI 1.00.HW02.4 and HBW2PER1 1.000.HW01.3 devices allow command spoofing (for camera control) after ARP cache poisoning has been achieved.

CVE-2021-39363 honeywell vulnerability CVSS: 7.5 24 Feb 2022, 22:15 UTC

Honeywell HDZP252DI 1.00.HW02.4 and HBW2PER1 1.000.HW01.3 devices allow a video replay attack after ARP cache poisoning has been achieved.

CVE-2020-27295 honeywell vulnerability CVSS: 5.0 26 Jan 2021, 20:15 UTC

The affected product has uncontrolled resource consumption issues, which may allow an attacker to cause a denial-of-service condition on the OPC UA Tunneller (versions prior to 6.3.0.8233).

CVE-2020-27299 honeywell vulnerability CVSS: 6.4 26 Jan 2021, 19:15 UTC

The affected product is vulnerable to an out-of-bounds read, which may allow an attacker to obtain and disclose sensitive data information or cause the device to crash on the OPC UA Tunneller (versions prior to 6.3.0.8233).

CVE-2020-27297 honeywell vulnerability CVSS: 7.5 26 Jan 2021, 19:15 UTC

The affected product is vulnerable to a heap-based buffer overflow, which may allow an attacker to manipulate memory with controlled values and remotely execute code on the OPC UA Tunneller (versions prior to 6.3.0.8233).

CVE-2020-27274 honeywell vulnerability CVSS: 5.0 26 Jan 2021, 19:15 UTC

Some parsing functions in the affected product do not check the return value of malloc and the thread handling the message is forced to close, which may lead to a denial-of-service condition on the OPC UA Tunneller (versions prior to 6.3.0.8233).

CVE-2020-10628 honeywell vulnerability CVSS: 5.0 26 Jun 2020, 17:15 UTC

ControlEdge PLC (R130.2, R140, R150, and R151) and RTU (R101, R110, R140, R150, and R151) exposes unencrypted passwords on the network.

CVE-2020-10624 honeywell vulnerability CVSS: 5.0 26 Jun 2020, 17:15 UTC

ControlEdge PLC (R130.2, R140, R150, and R151) and RTU (R101, R110, R140, R150, and R151) exposes a session token on the network.

CVE-2020-6974 honeywell vulnerability CVSS: 7.5 07 Apr 2020, 18:15 UTC

Honeywell Notifier Web Server (NWS) Version 3.50 is vulnerable to a path traversal attack, which allows an attacker to bypass access to restricted directories. Honeywell has released a firmware update to address the problem.

CVE-2020-6982 honeywell vulnerability CVSS: 5.8 24 Mar 2020, 21:15 UTC

In Honeywell WIN-PAK 4.7.2, Web and prior versions, the header injection vulnerability has been identified, which may allow remote code execution.

CVE-2020-6978 honeywell vulnerability CVSS: 6.4 24 Mar 2020, 21:15 UTC

In Honeywell WIN-PAK 4.7.2, Web and prior versions, the affected product is vulnerable due to the usage of old jQuery libraries.

CVE-2020-7005 honeywell vulnerability CVSS: 6.8 24 Mar 2020, 20:15 UTC

In Honeywell WIN-PAK 4.7.2, Web and prior versions, the affected product is vulnerable to a cross-site request forgery, which may allow an attacker to remotely execute arbitrary code.

CVE-2020-6972 honeywell vulnerability CVSS: 6.4 24 Mar 2020, 17:15 UTC

In Notifier Web Server (NWS) Version 3.50 and earlier, the Honeywell Fire Web Server’s authentication may be bypassed by a capture-replay attack from a web browser.

CVE-2020-6968 honeywell vulnerability CVSS: 4.6 20 Feb 2020, 21:15 UTC

Honeywell INNCOM INNControl 3 allows workstation users to escalate application user privileges through the modification of local configuration files.

CVE-2020-6960 honeywell vulnerability CVSS: 7.5 22 Jan 2020, 15:15 UTC

The following versions of MAXPRO VMS and NVR, MAXPRO VMS:HNMSWVMS prior to Version VMS560 Build 595 T2-Patch, HNMSWVMSLT prior to Version VMS560 Build 595 T2-Patch, MAXPRO NVR: MAXPRO NVR XE prior to Version NVR 5.6 Build 595 T2-Patch, MAXPRO NVR SE prior to Version NVR 5.6 Build 595 T2-Patch, MAXPRO NVR PE prior to Version NVR 5.6 Build 595 T2-Patch, and MPNVRSWXX prior to Version NVR 5.6 Build 595 T2-Patch contain an SQL injection vulnerability that could give an attacker remote unauthenticated access to the web user interface with administrator-level privileges.

CVE-2020-6959 honeywell vulnerability CVSS: 7.5 22 Jan 2020, 15:15 UTC

The following versions of MAXPRO VMS and NVR, MAXPRO VMS:HNMSWVMS prior to Version VMS560 Build 595 T2-Patch, HNMSWVMSLT prior to Version VMS560 Build 595 T2-Patch, MAXPRO NVR: MAXPRO NVR XE prior to Version NVR 5.6 Build 595 T2-Patch, MAXPRO NVR SE prior to Version NVR 5.6 Build 595 T2-Patch, MAXPRO NVR PE prior to Version NVR 5.6 Build 595 T2-Patch, and MPNVRSWXX prior to Version NVR 5.6 Build 595 T2-Patch are vulnerable to an unsafe deserialization of untrusted data. An attacker may be able to remotely modify deserialized data without authentication using a specially crafted web request, resulting in remote code execution.

CVE-2019-18230 honeywell vulnerability CVSS: 5.0 31 Oct 2019, 22:15 UTC

Honeywell equIP and Performance series IP cameras, multiple versions, A vulnerability exists where the affected product allows unauthenticated access to audio streaming over HTTP.

CVE-2019-18228 honeywell vulnerability CVSS: 5.0 31 Oct 2019, 22:15 UTC

Honeywell equIP series IP cameras Multiple equIP Series Cameras, A vulnerability exists in the affected products where a specially crafted HTTP packet request could result in a denial of service.

CVE-2019-18226 honeywell vulnerability CVSS: 7.5 31 Oct 2019, 22:15 UTC

Honeywell equIP series and Performance series IP cameras and recorders, A vulnerability exists in the affected products where IP cameras and recorders have a potential replay attack vulnerability as a weak authentication method is retained for compatibility with legacy products.

CVE-2019-13523 honeywell vulnerability CVSS: 5.0 26 Sep 2019, 16:15 UTC

In Honeywell Performance IP Cameras and Performance NVRs, the integrated web server of the affected devices could allow remote attackers to obtain web configuration data in JSON format for IP cameras and NVRs (Network Video Recorders), which can be accessed without authentication over the network. Affected performance IP Cameras: HBD3PR2,H4D3PRV3,HED3PR3,H4D3PRV2,HBD3PR1,H4W8PR2,HBW8PR2,H2W2PC1M,H2W4PER3,H2W2PER3,HEW2PER3,HEW4PER3B,HBW2PER1,HEW4PER2,HEW4PER2B,HEW2PER2,H4W2PER2,HBW2PER2,H4W2PER3, and HPW2P1. Affected Performance Series NVRs: HEN08104,HEN08144,HEN081124,HEN16104,HEN16144,HEN16184,HEN16204,HEN162244,HEN16284,HEN16304,HEN16384,HEN32104,HEN321124,HEN32204,HEN32284,HEN322164,HEN32304, HEN32384,HEN323164,HEN64204,HEN64304,HEN643164,HEN643324,HEN643484,HEN04103,HEN04113,HEN04123,HEN08103,HEN08113,HEN08123,HEN08143,HEN16103,HEN16123,HEN16143,HEN16163,HEN04103L,HEN08103L,HEN16103L,HEN32103L.

CVE-2014-9186 honeywell vulnerability CVSS: 7.5 08 Apr 2019, 16:29 UTC

A file inclusion vulnerability exists in the confd.exe module in Honeywell Experion PKS R40x before R400.6, R41x before R410.6, and R43x before R430.2, which could lead to accepting an arbitrary file into the function, and potential information disclosure or remote code execution. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version.

CVE-2014-5436 honeywell vulnerability CVSS: 5.0 08 Apr 2019, 16:29 UTC

A directory traversal vulnerability exists in the confd.exe module in Honeywell Experion PKS R40x before R400.6, R41x before R410.6, and R43x before R430.2, which could lead to possible information disclosure. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version.

CVE-2014-5435 honeywell vulnerability CVSS: 7.5 08 Apr 2019, 16:29 UTC

An arbitrary memory write vulnerability exists in the dual_onsrv.exe module in Honeywell Experion PKS R40x before R400.6, R41x before R410.6, and R43x before R430.2, that could lead to possible remote code execution or denial of service. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version.

CVE-2014-9189 honeywell vulnerability CVSS: 10.0 25 Mar 2019, 20:29 UTC

Multiple stack-based buffer overflow vulnerabilities were found in Honeywell Experion PKS all versions prior to R400.6, all versions prior to R410.6, and all versions prior to R430.2 modules that could lead to possible remote code execution, dynamic memory corruption, or denial of service. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version.

CVE-2014-9187 honeywell vulnerability CVSS: 7.5 25 Mar 2019, 20:29 UTC

Multiple heap-based buffer overflow vulnerabilities exist in Honeywell Experion PKS all versions prior to R400.6, all versions prior to R410.6, and all versions prior to R430.2 modules, which could lead to possible remote code execution or denial of service. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version.

CVE-2018-14825 honeywell vulnerability CVSS: 6.8 24 Sep 2018, 19:29 UTC

On Honeywell Mobile Computers (CT60 running Android OS 7.1, CN80 running Android OS 7.1, CT40 running Android OS 7.1, CK75 running Android OS 6.0, CN75 running Android OS 6.0, CN75e running Android OS 6.0, CT50 running Android OS 6.0, D75e running Android OS 6.0, CT50 running Android OS 4.4, D75e running Android OS 4.4, CN51 running Android OS 6.0, EDA50k running Android 4.4, EDA50 running Android OS 7.1, EDA50k running Android OS 7.1, EDA70 running Android OS 7.1, EDA60k running Android OS 7.1, and EDA51 running Android OS 8.1), a skilled attacker with advanced knowledge of the target system could exploit this vulnerability by creating an application that would successfully bind to the service and gain elevated system privileges. This could enable the attacker to obtain access to keystrokes, passwords, personal identifiable information, photos, emails, or business-critical documents.

CVE-2017-14263 honeywell vulnerability CVSS: 9.3 11 Sep 2017, 09:29 UTC

Honeywell NVR devices allow remote attackers to create a user account in the admin group by leveraging access to a guest account to obtain a session ID, and then sending that session ID in a userManager.addUser request to the /RPC2 URI. The attacker can login to the device with that new user account to fully control the device.

CVE-2017-5671 honeywell vulnerability CVSS: 7.2 29 Mar 2017, 14:59 UTC

Honeywell Intermec PM23, PM42, PM43, PC23, PC43, PD43, and PC42 industrial printers before 10.11.013310 and 10.12.x before 10.12.013309 have /usr/bin/lua installed setuid to the itadmin account, which allows local users to conduct a BusyBox jailbreak attack and obtain root privileges by overwriting the /etc/shadow file.

CVE-2017-5143 honeywell vulnerability CVSS: 7.5 13 Feb 2017, 21:59 UTC

An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-1-02-08 and prior. A user without authenticating can make a directory traversal attack by accessing a specific URL.

CVE-2017-5142 honeywell vulnerability CVSS: 6.5 13 Feb 2017, 21:59 UTC

An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-1-02-08 and prior. A user with low privileges is able to open and change the parameters by accessing a specific URL because of Improper Privilege Management.

CVE-2017-5141 honeywell vulnerability CVSS: 6.5 13 Feb 2017, 21:59 UTC

An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-1-02-08 and prior. An attacker can establish a new user session, without invalidating any existing session identifier, which gives the opportunity to steal authenticated sessions (SESSION FIXATION).

CVE-2017-5140 honeywell vulnerability CVSS: 5.0 13 Feb 2017, 21:59 UTC

An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-1-02-08 and prior. Password is stored in clear text.

CVE-2017-5139 honeywell vulnerability CVSS: 5.0 13 Feb 2017, 21:59 UTC

An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-1-02-08 and prior. Any user is able to disclose a password by accessing a specific URL, because of Plaintext Storage of a Password.

CVE-2016-8344 honeywell vulnerability CVSS: 4.3 13 Feb 2017, 21:59 UTC

An issue was discovered in Honeywell Experion Process Knowledge System (PKS) platform: Experion PKS, Release 3xx and prior, Experion PKS, Release 400, Experion PKS, Release 410, Experion PKS, Release 430, and Experion PKS, Release 431. Experion PKS does not properly validate input. By sending a specially crafted packet, an attacker could cause the process to terminate. A successful exploit would prevent firmware uploads to the Series-C devices.

CVE-2016-2280 honeywell vulnerability CVSS: 7.8 21 Apr 2016, 11:00 UTC

Buffer overflow in RDISERVER in Honeywell Uniformance Process History Database (PHD) R310, R320, and R321 allows remote attackers to cause a denial of service (service outage) via unspecified vectors.

CVE-2015-7908 honeywell vulnerability CVSS: 9.3 21 Dec 2015, 11:59 UTC

Honeywell Midas gas detectors before 1.13b3 and Midas Black gas detectors before 2.13b3 allow remote attackers to discover cleartext passwords by sniffing the network.

CVE-2015-7907 honeywell vulnerability CVSS: 6.4 21 Dec 2015, 11:59 UTC

Directory traversal vulnerability in the web server on Honeywell Midas gas detectors before 1.13b3 and Midas Black gas detectors before 2.13b3 allows remote attackers to bypass authentication, and write to a configuration file or trigger a calibration or test, via unspecified vectors.

CVE-2015-0984 honeywell vulnerability CVSS: 10.0 31 Mar 2015, 01:59 UTC

Directory traversal vulnerability in the FTP server on Honeywell Excel Web XL1000C50 52 I/O, XL1000C100 104 I/O, XL1000C500 300 I/O, XL1000C1000 600 I/O, XL1000C50U 52 I/O UUKL, XL1000C100U 104 I/O UUKL, XL1000C500U 300 I/O UUKL, and XL1000C1000U 600 I/O UUKL controllers before 2.04.01 allows remote attackers to read files under the web root, and consequently obtain administrative login access, via a crafted pathname.

CVE-2014-3110 honeywell vulnerability CVSS: 4.3 24 Jul 2014, 14:55 UTC

Multiple cross-site scripting (XSS) vulnerabilities on Honeywell FALCON XLWeb Linux controller devices 2.04.01 and earlier and FALCON XLWeb XLWebExe controller devices 2.02.11 and earlier allow remote attackers to inject arbitrary web script or HTML via invalid input.

CVE-2014-2717 honeywell vulnerability CVSS: 7.6 24 Jul 2014, 14:55 UTC

Honeywell FALCON XLWeb Linux controller devices 2.04.01 and earlier and FALCON XLWeb XLWebExe controller devices 2.02.11 and earlier allow remote attackers to bypass authentication and obtain administrative access by visiting the change-password page.

CVE-2013-0108 honeywell vulnerability CVSS: 6.8 24 Feb 2013, 11:48 UTC

An ActiveX control in HscRemoteDeploy.dll in Honeywell Enterprise Buildings Integrator (EBI) R310, R400.2, R410.1, and R410.2; SymmetrE R310, R410.1, and R410.2; ComfortPoint Open Manager (aka CPO-M) Station R100; and HMIWeb Browser client packages allows remote attackers to execute arbitrary code via a crafted HTML document.

CVE-2012-0254 honeywell vulnerability CVSS: 7.5 08 Sep 2012, 10:28 UTC

Stack-based buffer overflow in the HMIWeb Browser HSCDSPRenderDLL ActiveX control in Honeywell Process Solutions (HPS) Experion R2xx, R30x, R31x, and R400.x; Honeywell Building Solutions (HBS) Enterprise Building Manager R400 and R410.1; and Honeywell Environmental Combustion and Controls (ECC) SymmetrE R410.1 allows remote attackers to execute arbitrary code via unspecified vectors.

CVE-2011-0331 honeywell vulnerability CVSS: 9.3 22 Mar 2011, 17:55 UTC

Use-after-free vulnerability in the addOSPLext method in the Honeywell ScanServer ActiveX control 780.0.20.5 allows remote attackers to execute arbitrary code via a crafted HTML document.

CVE-2007-2938 honeywell vulnerability CVSS: 10.0 31 May 2007, 00:30 UTC

Buffer overflow in the BaseRunner ActiveX control in the Ademco ATNBaseLoader100 Module (ATNBaseLoader100.dll) 5.4.0.6, when Internet Explorer 6 is used, allows remote attackers to execute arbitrary code via a long argument to the (1) Send485CMD method, and possibly the (2) SetLoginID, (3) AddSite, (4) SetScreen, and (5) SetVideoServer methods.