Focus on swtchenergy vulnerabilities and metrics.
Last updated: 08 Mar 2026, 23:25 UTC
This page consolidates all known Common Vulnerabilities and Exposures (CVEs) associated with swtchenergy. We track both calendar-based metrics (using fixed periods) and rolling metrics (using gliding windows) to give you a comprehensive view of security trends and risk evolution. Use these insights to assess risk and plan your patching strategy.
For a broader perspective on cybersecurity threats, explore the comprehensive list of CVEs by vendor and product. Stay updated on critical vulnerabilities affecting major software and hardware providers.
Total swtchenergy CVEs: 4
Earliest CVE date: 27 Feb 2026, 00:16 UTC
Latest CVE date: 27 Feb 2026, 00:16 UTC
Latest CVE reference: CVE-2026-27773
30-day Count (Rolling): 4
365-day Count (Rolling): 4
Calendar-based Variation
Calendar-based Variation compares a fixed calendar period (e.g., this month versus the same month last year), while Rolling Growth Rate uses a continuous window (e.g., last 30 days versus the previous 30 days) to capture trends independent of calendar boundaries.
Month Variation (Calendar): 0%
Year Variation (Calendar): 0%
Month Growth Rate (30-day Rolling): 0.0%
Year Growth Rate (365-day Rolling): 0.0%
Average CVSS: 0.0
Max CVSS: 0
Critical CVEs (≥9): 0
| Range | Count |
|---|---|
| 0.0-3.9 | 4 |
| 4.0-6.9 | 0 |
| 7.0-8.9 | 0 |
| 9.0-10.0 | 0 |
These are the five CVEs with the highest CVSS scores for swtchenergy, sorted by severity first and recency.
Charging station authentication identifiers are publicly accessible via web-based mapping platforms.
WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend.
The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests.
The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or mis-routing legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access.