This page consolidates all known Common Vulnerabilities and Exposures (CVEs) associated with gehealthcare. We track both calendar-based metrics (using fixed periods) and rolling metrics (using gliding windows) to give you a comprehensive view of security trends and risk evolution. Use these insights to assess risk and plan your patching strategy.
For a broader perspective on cybersecurity threats, explore the comprehensive list of CVEs by vendor and product. Stay updated on critical vulnerabilities affecting major software and hardware providers.
Total gehealthcare CVEs: 34
Earliest CVE date: 04 Aug 2015, 14:59 UTC
Latest CVE date: 14 Dec 2020, 17:15 UTC
Latest CVE reference: CVE-2020-25179
30-day Count (Rolling): 0
365-day Count (Rolling): 0
Calendar-based Variation
Calendar-based Variation compares a fixed calendar period (e.g., this month versus the same month last year), while Rolling Growth Rate uses a continuous window (e.g., last 30 days versus the previous 30 days) to capture trends independent of calendar boundaries.
Month Variation (Calendar): 0%
Year Variation (Calendar): 0%
Month Growth Rate (30-day Rolling): 0.0%
Year Growth Rate (365-day Rolling): 0.0%
Average CVSS: 9.46
Max CVSS: 10.0
Critical CVEs (≥9): 29
Range | Count |
---|---|
0.0-3.9 | 0 |
4.0-6.9 | 3 |
7.0-8.9 | 2 |
9.0-10.0 | 29 |
These are the five CVEs with the highest CVSS scores for gehealthcare, sorted by severity first and recency.
GE Healthcare Imaging and Ultrasound Products may allow specific credentials to be exposed during transport over the network.
GE Healthcare Imaging and Ultrasound Products may allow specific credentials to be exposed during transport over the network.
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, the affected products utilize a weak encryption scheme for remote desktop control, which may allow an attacker to obtain remote code execution of devices on the network.
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, a vulnerability in the software update mechanism allows an authenticated attacker to upload arbitrary files on the system through a crafted update package.
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X and CARESCAPE Central Station (CSCS) Versions 2.X, the integrated service for keyboard switching of the affected devices could allow attackers to obtain remote keyboard input access without authentication over the network.
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, the affected products utilized hard coded SMB credentials, which may allow an attacker to remotely execute arbitrary code.
In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X CARESCAPE Central Station (CSCS) Versions 2.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, an input validation vulnerability exists in the web-based system configuration utility that could allow an attacker to obtain arbitrary remote code execution.
In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X, a vulnerability exists in the affected products that could allow an attacker to obtain access to the SSH private key in configuration files.
GE Healthcare Centricity Clinical Archive Audit Trail Repository has a default password of initinit for the (1) SSL key manager and (2) server keystore; (3) keystore_password for the server truststore; and atna for the (4) primary storage database and (5) archive storage database, which has unspecified impact and attack vectors.
GE Healthcare Precision THUNIS-800+ has a default password of (1) 1973 for the factory default System Utilities menu, (2) TH8740 for installation using TH8740_122_Setup.exe, (3) hrml for "Setup and Activation" using DSASetup, and (4) an empty string for Shutter Configuration, which has unspecified impact and attack vectors. NOTE: since these passwords appear to be used to access functionality during installation, this issue might not cross privilege boundaries and might not be a vulnerability.
GE Healthcare Discovery XR656 and XR656 G2 has a password of (1) 2getin for the insite user, (2) 4$xray for the xruser user, and (3) #superxr for the root user, which has unspecified impact and attack vectors. NOTE: it is not clear whether these passwords are default, hardcoded, or dependent on another system or product that requires a fixed value.
GE Healthcare Centricity PACS Workstation 4.0 and 4.0.1 has a password of (1) CANal1 for the Administrator user and (2) iis for the IIS user, which has unspecified impact and attack vectors related to TimbuktuPro. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires it.
The Ad Hoc Reporting feature in GE Healthcare Centricity DMS 4.2 has a password of Never!Mind for the Administrator user, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value.
GE Healthcare Discovery NM 750b has a password of 2getin for the insite account for (1) Telnet and (2) FTP, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value.
GE Healthcare Centricity PACS Workstation 4.0 and 4.0.1 has a password of ddpadmin for the ddpadmin user, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value.
GE Healthcare Centricity PACS Workstation 4.0 and 4.0.1, and Server 4.0, has a password of 2charGE for the geservice account, which has unspecified impact and attack vectors related to TimbuktuPro. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires it.
GE Healthcare Centricity PACS 4.0 Server has a default password of (1) nasro for the nasro (ReadOnly) user and (2) nasrw for the nasrw (Read/Write) user, which has unspecified impact and attack vectors.
GE Healthcare Precision MPi has a password of (1) orion for the serviceapp user, (2) orion for the clinical operator user, and (3) PlatinumOne for the administrator user, which has unspecified impact and attack vectors. NOTE: it is not clear whether these passwords are default, hardcoded, or dependent on another system or product that requires a fixed value.
The TeraRecon server, as used in GE Healthcare Centricity PACS-IW 3.7.3.7, 3.7.3.8, and possibly other versions, has a password of (1) shared for the shared user and (2) scan for the scan user, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value.
GE Healthcare Centricity PACS-IW 3.7.3.7, 3.7.3.8, and possibly other versions has a password of A11enda1e for the sa SQL server user, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value.
GE Healthcare Centricity Analytics Server 1.1 has a default password of (1) V0yag3r for the SQL Server sa user, (2) G3car3s for the analyst user, (3) G3car3s for the ccg user, (4) V0yag3r for the viewer user, and (5) geservice for the geservice user in the Webmin interface, which has unspecified impact and attack vectors.
The Acquisition Workstation for the GE Healthcare Revolution XQ/i has a password of adw3.1 for the sdc user, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value.
GE Healthcare CADStream Server has a default password of confirma for the admin user, which has unspecified impact and attack vectors.
GE Healthcare Optima MR360 does not require authentication for the HIPAA emergency login procedure, which allows physically proximate users to gain access via an arbitrary username in the Emergency Login screen. NOTE: this might not qualify for inclusion in CVE if unauthenticated emergency access is part of the intended security policy of the product, can be controlled by the system administrator, and is not enabled by default.
The HIPAA configuration interface in GE Healthcare Optima MR360 has a password of (1) operator for the root account, (2) adw2.0 for the admin account, and (3) adw2.0 for the sdc account, which has unspecified impact and attack vectors. NOTE: it is not clear whether these passwords are default, hardcoded, or dependent on another system or product that requires a fixed value.
GE Healthcare Optima CT680, CT540, CT640, and CT520 has a default password of #bigguy for the root user, which has unspecified impact and attack vectors.
GE Healthcare Discovery 530C has a password of #bigguy1 for the (1) acqservice user and (2) wsservice user of the Xeleris System, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value.
GE Healthcare Centricity DMS 4.2, 4.1, and 4.0 has a password of Muse!Admin for the Museadmin user, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value.
GE Healthcare Infinia II has a default password of (1) infinia for the infinia user, (2) #bigguy1 for the acqservice user, (3) dont4get2 for the Administrator user, (4) #bigguy1 for the emergency user, and (5) 2Bfamous for the InfiniaAdmin user, which has unspecified impact and attack vectors.
GE Healthcare Centricity Image Vault 3.x has a password of (1) gemnet for the administrator account, (2) webadmin for the webadmin administrator account of the ASACA DVD library, (3) an empty value for the gemsservice account of the Ultrasound Database, and possibly (4) gemnet2002 for the gemnet2002 account of the GEMNet license server, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value.
GE Healthcare Discovery VH has a default password of (1) interfile for the ftpclient user of the Interfile server or (2) "2" for the LOCAL user of the FTP server for the Codonics printer, which has unspecified impact and attack vectors.
GE Healthcare Millennium MG, NC, and MyoSIGHT has a password of insite.genieacq for the insite account that cannot be changed without disabling product functionality for remote InSite support, which has unspecified impact and attack vectors.
GE Healthcare Millennium MG, NC, and MyoSIGHT has a default password of (1) root.genie for the root user, (2) "service." for the service user, (3) admin.genie for the admin user, (4) reboot for the reboot user, and (5) shutdown for the shutdown user, which has unspecified impact and attack vectors.
GE Healthcare eNTEGRA P&R has a password of (1) entegra for the entegra user, (2) passme for the super user of the Polestar/Polestar-i Starlink 4 upgrade, (3) 0 for the entegra user of the Codonics printer FTP service, (4) eNTEGRA for the eNTEGRA P&R user account, (5) insite for the WinVNC Login, and possibly other accounts, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value.