Focus on flir vulnerabilities and metrics.
Last updated: 08 Mar 2025, 23:25 UTC
This page consolidates all known Common Vulnerabilities and Exposures (CVEs) associated with flir. We track both calendar-based metrics (using fixed periods) and rolling metrics (using gliding windows) to give you a comprehensive view of security trends and risk evolution. Use these insights to assess risk and plan your patching strategy.
For a broader perspective on cybersecurity threats, explore the comprehensive list of CVEs by vendor and product. Stay updated on critical vulnerabilities affecting major software and hardware providers.
Total flir CVEs: 10
Earliest CVE date: 01 Jan 2018, 20:29 UTC
Latest CVE date: 10 Jan 2024, 21:15 UTC
Latest CVE reference: CVE-2023-51127
30-day Count (Rolling): 0
365-day Count (Rolling): 0
Calendar-based Variation
Calendar-based Variation compares a fixed calendar period (e.g., this month versus the same month last year), while Rolling Growth Rate uses a continuous window (e.g., last 30 days versus the previous 30 days) to capture trends independent of calendar boundaries.
Month Variation (Calendar): 0%
Year Variation (Calendar): -100.0%
Month Growth Rate (30-day Rolling): 0.0%
Year Growth Rate (365-day Rolling): -100.0%
Average CVSS: 1.0
Max CVSS: 5.0
Critical CVEs (≥9): 0
Range | Count |
---|---|
0.0-3.9 | 8 |
4.0-6.9 | 2 |
7.0-8.9 | 0 |
9.0-10.0 | 0 |
These are the five CVEs with the highest CVSS scores for flir, sorted by severity first and recency.
FLIR AX8 thermal sensor cameras up to and including 1.46.16 are vulnerable to Directory Traversal due to improper access restriction. This vulnerability allows an unauthenticated, remote attacker to obtain arbitrary sensitive file contents by uploading a specially crafted symbolic link file.
Command injection vulnerability in /usr/www/res.php in FLIR AX8 up to 1.46.16 allows attackers to run arbitrary commands via the value parameter.
An issue found in FLIR-DVTEL version not specified allows a remote attacker to execute arbitrary code via a crafted request to the management page of the device.
A vulnerability classified as critical has been found in Teledyne FLIR AX8 up to 1.46.16. Affected is an unknown function of the file palette.php of the component Web Service Handler. The manipulation of the argument palette leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-215118 is the identifier assigned to this vulnerability.
All FLIR AX8 thermal sensor cameras versions up to and including 1.46.16 are vulnerable to Cross Site Scripting (XSS) due to improper input sanitization. An authenticated remote attacker can execute arbitrary JavaScript code in the web management interface. A successful exploit could allow the attacker to insert malicious JavaScript code.
All FLIR AX8 thermal sensor cameras version up to and including 1.46.16 are affected by an insecure design vulnerability due to an improper directory access restriction. An unauthenticated, remote attacker can exploit this by sending a URI that contains the path of the SQLite users database and download it. A successful exploit could allow the attacker to extract usernames and hashed passwords.
All FLIR AX8 thermal sensor cameras version up to and including 1.46.16 are vulnerable to Remote Command Injection. This can be exploited to inject and execute arbitrary shell commands as the root user through the id HTTP POST parameter in the res.php endpoint. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with the root privileges.
FLIR AX8 thermal sensor cameras version up to and including 1.46.16 is vulnerable to Directory Traversal due to an improper access restriction. An unauthenticated, remote attacker can exploit this by sending a URI that contains directory traversal characters to disclose the contents of files located outside of the server's restricted path.
Brickstream 2300 devices allow remote attackers to obtain potentially sensitive information via a direct request for the basic.html#ipsettings or basic.html#datadelivery URI.
getConfigExportFile.cgi on FLIR Brickstream 2300 devices 2.0 4.1.53.166 has Incorrect Access Control, as demonstrated by reading the AVI_USER_ID and AVI_USER_PASSWORD fields via a direct request.