draeger CVE Vulnerabilities & Metrics

Focus on draeger vulnerabilities and metrics.

Last updated: 01 Oct 2026, 22:25 UTC

About draeger Security Exposure

This page consolidates all known Common Vulnerabilities and Exposures (CVEs) associated with draeger. We track both calendar-based metrics (using fixed periods) and rolling metrics (using gliding windows) to give you a comprehensive view of security trends and risk evolution. Use these insights to assess risk and plan your patching strategy.

For a broader perspective on cybersecurity threats, explore the comprehensive list of CVEs by vendor and product. Stay updated on critical vulnerabilities affecting major software and hardware providers.

Global CVE Overview

Total draeger CVEs: 8
Earliest CVE date: 28 Jan 2019, 21:29 UTC
Latest CVE date: 02 Jun 2026, 14:16 UTC

Latest CVE reference: CVE-2019-25717

Rolling Stats

30-day Count (Rolling): 0
365-day Count (Rolling): 3

Calendar-based Variation

Calendar-based Variation compares a fixed calendar period (e.g., this month versus the same month last year), while Rolling Growth Rate uses a continuous window (e.g., last 30 days versus the previous 30 days) to capture trends independent of calendar boundaries.

Variations & Growth

Month Variation (Calendar): 0%
Year Variation (Calendar): 0%

Month Growth Rate (30-day Rolling): 0.0%
Year Growth Rate (365-day Rolling): 0.0%

Monthly CVE Trends (current vs previous Year)

Annual CVE Trends (Last 20 Years)

Critical draeger CVEs (CVSS ≥ 9) Over 20 Years

CVSS Stats

Average CVSS: 3.35

Max CVSS: 7.2

Critical CVEs (≥9): 0

CVSS Range vs. Count

Range Count
0.0-3.9 5
4.0-6.9 2
7.0-8.9 1
9.0-10.0 0

CVSS Distribution Chart

Top 5 Highest CVSS draeger CVEs

These are the five CVEs with the highest CVSS scores for draeger, sorted by severity first and recency.

All CVEs for draeger

CVE-2019-25717 draeger vulnerability CVSS: 0 02 Jun 2026, 14:16 UTC

Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain an information disclosure vulnerability that allows unauthenticated network attackers to access log files over a network connection. Attackers can retrieve device internals, location information, and wired network configuration details from the exposed log files.

CVE-2019-25718 draeger vulnerability CVSS: 0 01 Jun 2026, 23:16 UTC

Dräger Infinity Explorer C700 contains a privilege escalation vulnerability that allows attackers to break out of kiosk mode and access the underlying operating system through a specific dialog interaction. Attackers can exploit this kiosk escape to take control of the operating system and cause the device to display incorrect or no information from the connected Delta Family patient monitor.

CVE-2019-25716 draeger vulnerability CVSS: 0 01 Jun 2026, 22:16 UTC

Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause the monitor to reboot by sending a malformed network packet. Attackers can repeatedly send malformed network packets to disrupt patient monitoring until the device falls back to default configuration and loses network connectivity.

CVE-2021-28112 draeger vulnerability CVSS: 6.5 20 May 2021, 14:15 UTC

Draeger X-Dock Firmware before 03.00.13 has Active Debug Code on a debug port, leading to remote code execution by an authenticated attacker.

CVE-2021-28111 draeger vulnerability CVSS: 6.5 20 May 2021, 14:15 UTC

Draeger X-Dock Firmware before 03.00.13 has Hard-Coded Credentials, leading to remote code execution by an authenticated attacker.

CVE-2018-19014 draeger vulnerability CVSS: 3.3 28 Jan 2019, 22:29 UTC

Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. Log files are accessible over an unauthenticated network connection. By accessing the log files, an attacker is able to gain insights about internals of the patient monitor, the location of the monitor, and wired network configuration.

CVE-2018-19010 draeger vulnerability CVSS: 3.3 28 Jan 2019, 22:29 UTC

Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. A malformed network packet may cause the monitor to reboot. By repeatedly sending the malformed network packet, an attacker may be able to disrupt patient monitoring by causing the monitor to repeatedly reboot until it falls back to default configuration and loses network connectivity.

CVE-2018-19012 draeger vulnerability CVSS: 7.2 28 Jan 2019, 21:29 UTC

Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. Via a specific dialog it is possible to break out of the kiosk mode and reach the underlying operating system. By breaking out of the kiosk mode, an attacker is able to take control of the operating system.