Focus on contec vulnerabilities and metrics.
Last updated: 08 Mar 2025, 23:25 UTC
This page consolidates all known Common Vulnerabilities and Exposures (CVEs) associated with contec. We track both calendar-based metrics (using fixed periods) and rolling metrics (using gliding windows) to give you a comprehensive view of security trends and risk evolution. Use these insights to assess risk and plan your patching strategy.
For a broader perspective on cybersecurity threats, explore the comprehensive list of CVEs by vendor and product. Stay updated on critical vulnerabilities affecting major software and hardware providers.
Total contec CVEs: 43
Earliest CVE date: 14 Mar 2014, 15:55 UTC
Latest CVE date: 27 Oct 2023, 21:15 UTC
Latest CVE reference: CVE-2023-46509
30-day Count (Rolling): 0
365-day Count (Rolling): 0
Calendar-based Variation
Calendar-based Variation compares a fixed calendar period (e.g., this month versus the same month last year), while Rolling Growth Rate uses a continuous window (e.g., last 30 days versus the previous 30 days) to capture trends independent of calendar boundaries.
Month Variation (Calendar): 0%
Year Variation (Calendar): -100.0%
Month Growth Rate (30-day Rolling): 0.0%
Year Growth Rate (365-day Rolling): -100.0%
Average CVSS: 1.7
Max CVSS: 10.0
Critical CVEs (≥9): 2
Range | Count |
---|---|
0.0-3.9 | 32 |
4.0-6.9 | 9 |
7.0-8.9 | 1 |
9.0-10.0 | 2 |
These are the five CVEs with the highest CVSS scores for contec, sorted by severity first and recency.
An issue in Contec SolarView Compact v.6.0 and before allows an attacker to execute arbitrary code via the texteditor.php component.
SolarView Compact < 6.00 is vulnerable to Directory Traversal.
SQL injection vulnerability exists in the CONPROSYS HMI System (CHS) versions prior to 3.5.3. A user who can access the affected product with an administrative privilege may execute an arbitrary SQL command via specially crafted input to the query setting page.
Server-side request forgery vulnerability exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. A user who can access the affected product with an administrative privilege may bypass the database restriction set on the query setting page, and connect to a user unintended database.
Plaintext storage of a password exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. Because account information of the database is saved in a local file in plaintext, a user who can access the PC where the affected product is installed can obtain the information. As a result, information in the database may be obtained and/or altered by the user.
Improper access control vulnerability exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. A user of the PC where the affected product is installed may gain an administrative privilege. As a result, information regarding the product may be obtained and/or altered by the user.
Cross-site scripting vulnerability exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. If a user who can access the affected product with an administrative privilege configures specially crafted settings, an arbitrary script may be executed on the web browser of the other user who is accessing the affected product with an administrative privilege.
Incorrect permission assignment for critical resource exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. ACL (Access Control List) is not appropriately set to the local folder where the affected product is installed, therefore a wide range of privileges is permitted to a user of the PC where the affected product is installed. As a result, the user may be able to destroy the system and/or execute a malicious program.
A denial of service vulnerability exists in Contec CONPROSYS HMI System versions 3.5.2 and prior. When there is a time-zone mismatch in certain configuration files, a remote, unauthenticated attacker may deny logins for an extended period of time.
Improper access control vulnerability in the system date/time setting page of SolarView Compact SV-CPT-MC310 versions prior to Ver.8.10 and SV-CPT-MC310F versions prior to Ver.8.10 allows a remote authenticated attacker to alter system date/time of the affected product.
OS command injection vulnerability in the mail setting page of SolarView Compact SV-CPT-MC310 versions prior to Ver.8.10 and SV-CPT-MC310F versions prior to Ver.8.10 allows remote authenticated attackers to execute an arbitrary OS command.
Buffer overflow vulnerability in the multiple setting pages of SolarView Compact SV-CPT-MC310 versions prior to Ver.8.10 and SV-CPT-MC310F versions prior to Ver.8.10 allows a remote authenticated attacker to execute arbitrary code.
OS command injection vulnerability in the download page of SolarView Compact SV-CPT-MC310 versions prior to Ver.8.10 and SV-CPT-MC310F versions prior to Ver.8.10 allows a remote authenticated attacker to execute an arbitrary OS command.
Use of hard-coded credentials exists in SolarView Compact SV-CPT-MC310 versions prior to Ver.8.10, and SV-CPT-MC310F versions prior to Ver.8.10, which may allow a remote authenticated attacker to login the affected product with an administrative privilege and perform an unintended operation.
SolarView Compact <= 6.0 is vulnerable to Insecure Permissions. Any file on the server can be read or modified because texteditor.php is not restricted.
OS command injection vulnerability in CONPROSYS IoT Gateway products allows a remote authenticated attacker who can access Network Maintenance page to execute arbitrary OS commands with a root privilege. The affected products and versions are as follows: M2M Gateway with the firmware Ver.3.7.10 and earlier (CPS-MG341-ADSC1-111, CPS-MG341-ADSC1-931, CPS-MG341G-ADSC1-111, CPS-MG341G-ADSC1-930, and CPS-MG341G5-ADSC1-931), M2M Controller Integrated Type with firmware Ver.3.7.6 and earlier versions (CPS-MC341-ADSC1-111, CPS-MC341-ADSC1-931, CPS-MC341-ADSC2-111, CPS-MC341G-ADSC1-110, CPS-MC341Q-ADSC1-111, CPS-MC341-DS1-111, CPS-MC341-DS11-111, CPS-MC341-DS2-911, and CPS-MC341-A1-111), and M2M Controller Configurable Type with firmware Ver.3.8.8 and earlier versions (CPS-MCS341-DS1-111, CPS-MCS341-DS1-131, CPS-MCS341G-DS1-130, CPS-MCS341G5-DS1-130, and CPS-MCS341Q-DS1-131).
Inadequate encryption strength vulnerability in CONPROSYS IoT Gateway products allows a remote authenticated attacker with an administrative privilege to apply a specially crafted Firmware update file, alter the information, cause a denial-of-service (DoS) condition, and/or execute arbitrary code. The affected products and versions are as follows: M2M Gateway with the firmware Ver.3.7.10 and earlier (CPS-MG341-ADSC1-111, CPS-MG341-ADSC1-931, CPS-MG341G-ADSC1-111, CPS-MG341G-ADSC1-930, and CPS-MG341G5-ADSC1-931), M2M Controller Integrated Type with firmware Ver.3.7.6 and earlier versions (CPS-MC341-ADSC1-111, CPS-MC341-ADSC1-931, CPS-MC341-ADSC2-111, CPS-MC341G-ADSC1-110, CPS-MC341Q-ADSC1-111, CPS-MC341-DS1-111, CPS-MC341-DS11-111, CPS-MC341-DS2-911, and CPS-MC341-A1-111), and M2M Controller Configurable Type with firmware Ver.3.8.8 and earlier versions (CPS-MCS341-DS1-111, CPS-MCS341-DS1-131, CPS-MCS341G-DS1-130, CPS-MCS341G5-DS1-130, and CPS-MCS341Q-DS1-131).
Improper access control vulnerability in CONPROSYS IoT Gateway products allows a remote authenticated attacker to bypass access restriction and access Network Maintenance page, which may result in obtaining the network information of the product. The affected products and versions are as follows: M2M Gateway with the firmware Ver.3.7.10 and earlier (CPS-MG341-ADSC1-111, CPS-MG341-ADSC1-931, CPS-MG341G-ADSC1-111, CPS-MG341G-ADSC1-930, and CPS-MG341G5-ADSC1-931), M2M Controller Integrated Type with firmware Ver.3.7.6 and earlier versions (CPS-MC341-ADSC1-111, CPS-MC341-ADSC1-931, CPS-MC341-ADSC2-111, CPS-MC341G-ADSC1-110, CPS-MC341Q-ADSC1-111, CPS-MC341-DS1-111, CPS-MC341-DS11-111, CPS-MC341-DS2-911, and CPS-MC341-A1-111), and M2M Controller Configurable Type with firmware Ver.3.8.8 and earlier versions (CPS-MCS341-DS1-111, CPS-MCS341-DS1-131, CPS-MCS341G-DS1-130, CPS-MCS341G5-DS1-130, and CPS-MCS341Q-DS1-131).
There is a command injection vulnerability in SolarView Compact through 6.00, attackers can execute commands by bypassing internal restrictions through downloader.php.
SQL injection vulnerability in the CONPROSYS HMI System (CHS) Ver.3.5.0 and earlier allows a remote authenticated attacker to execute an arbitrary SQL command. As a result, information stored in the database may be obtained.
Cross-site scripting vulnerability in CONPROSYS HMI System (CHS) Ver.3.4.5 and earlier allows a remote authenticated attacker to inject an arbitrary script and obtain the sensitive information.
Improper access control vulnerability in CONPROSYS HMI System (CHS) Ver.3.4.5 and earlier allows a remote unauthenticated attacker to bypass access restriction and obtain the server certificate including the private key of the product.
Use of password hash instead of password for authentication vulnerability in CONPROSYS HMI System (CHS) Ver.3.4.5 and earlier allows a remote authenticated attacker to obtain user credentials information via a man-in-the-middle attack.
Use of default credentials vulnerability in CONPROSYS HMI System (CHS) Ver.3.4.5 and earlier allows a remote unauthenticated attacker to alter user credentials information.
CONPROSYS HMI System (CHS) Ver.3.4.4?and earlier allows a remote unauthenticated attacker to execute an arbitrary OS command on the server where the product is running by sending a specially crafted request.
SolarView Compact 7.0 is vulnerable to Cross-site Scripting (XSS) via /network_test.php.
SolarView Compact 4.0 and 5.0 is vulnerable to Unrestricted File Upload via a crafted php file.
SolarView Compact 6.00 was discovered to contain a command injection vulnerability via network_test.php
Contec FXA3200 version 1.13 and under were discovered to contain a hard coded hash password for root stored in the component /etc/shadow. As the password strength is weak, it can be cracked in few minutes. Through this credential, a malicious actor can access the Wireless LAN Manager interface and open the telnet port then sniff the traffic or inject any malware.
Contec FXA3200 version 1.13.00 and under suffers from Insecure Permissions in the Wireless LAN Manager interface which allows malicious actors to execute Linux commands with root privilege via a hidden web page (/usr/www/ja/mnt_cmd.cgi).
The image file management page of SolarView Compact SV-CPT-MC310 Ver.7.23 and earlier, and SV-CPT-MC310F Ver.7.23 and earlier contains an insufficient verification vulnerability when uploading files. If this vulnerability is exploited, arbitrary PHP code may be executed if a remote authenticated attacker uploads a specially crafted PHP file.
An arbitrary file upload vulnerability /images/background/1.php in of SolarView Compact 6.0 allows attackers to execute arbitrary code via a crafted php file.
SolarView Compact v6.0 was discovered to contain a cross-site scripting (XSS) vulnerability via the component Solar_AiConf.php.
SolarView Compact ver.6.00 was discovered to contain a command injection vulnerability via conf_mail.php.
SolarView Compact ver.6.00 was discovered to contain a local file disclosure via /html/Solar_Ftp.php.
SolarView Compact ver.6.00 allows attackers to access sensitive files via directory traversal.
Missing authentication for critical function in SolarView Compact SV-CPT-MC310 prior to Ver.6.5 allows an attacker to alter the setting information without the access privileges via unspecified vectors.
Directory traversal vulnerability in SolarView Compact SV-CPT-MC310 prior to Ver.6.5 allows authenticated attackers to delete arbitrary files and/or directories on the server via unspecified vectors.
Cross-site scripting vulnerability in SolarView Compact SV-CPT-MC310 prior to Ver.6.5 allows an attacker to inject an arbitrary script via unspecified vectors.
SolarView Compact SV-CPT-MC310 prior to Ver.6.5 allows an authenticated attacker to upload arbitrary files via unspecified vectors. If the file is PHP script, an attacker may execute arbitrary code.
SolarView Compact SV-CPT-MC310 prior to Ver.6.5 allows an attacker to execute arbitrary OS commands with the web server privilege via unspecified vectors.
Improper access control vulnerability in SolarView Compact SV-CPT-MC310 prior to Ver.6.5 allows an authenticated attacker to obtain and/or alter the setting information without the access privilege via unspecified vectors.
Exposure of information through directory listing in SolarView Compact SV-CPT-MC310 prior to Ver.6.5 allows an authenticated attacker to obtain the information inside the system, such as directories and/or file configurations via unspecified vectors.
Multiple directory traversal vulnerabilities in (1) mod_evhost and (2) mod_simple_vhost in lighttpd before 1.4.35 allow remote attackers to read arbitrary files via a .. (dot dot) in the host name, related to request_check_hostname.