bbraun CVE Vulnerabilities & Metrics

Focus on bbraun vulnerabilities and metrics.

Last updated: 16 Apr 2025, 22:25 UTC

About bbraun Security Exposure

This page consolidates all known Common Vulnerabilities and Exposures (CVEs) associated with bbraun. We track both calendar-based metrics (using fixed periods) and rolling metrics (using gliding windows) to give you a comprehensive view of security trends and risk evolution. Use these insights to assess risk and plan your patching strategy.

For a broader perspective on cybersecurity threats, explore the comprehensive list of CVEs by vendor and product. Stay updated on critical vulnerabilities affecting major software and hardware providers.

Global CVE Overview

Total bbraun CVEs: 21
Earliest CVE date: 30 Jun 2017, 03:29 UTC
Latest CVE date: 13 Mar 2023, 09:15 UTC

Latest CVE reference: CVE-2023-0888

Rolling Stats

30-day Count (Rolling): 0
365-day Count (Rolling): 0

Calendar-based Variation

Calendar-based Variation compares a fixed calendar period (e.g., this month versus the same month last year), while Rolling Growth Rate uses a continuous window (e.g., last 30 days versus the previous 30 days) to capture trends independent of calendar boundaries.

Variations & Growth

Month Variation (Calendar): 0%
Year Variation (Calendar): 0%

Month Growth Rate (30-day Rolling): 0.0%
Year Growth Rate (365-day Rolling): 0.0%

Monthly CVE Trends (current vs previous Year)

Annual CVE Trends (Last 20 Years)

Critical bbraun CVEs (CVSS ≥ 9) Over 20 Years

CVSS Stats

Average CVSS: 6.0

Max CVSS: 10.0

Critical CVEs (≥9): 3

CVSS Range vs. Count

Range Count
0.0-3.9 2
4.0-6.9 12
7.0-8.9 4
9.0-10.0 3

CVSS Distribution Chart

Top 5 Highest CVSS bbraun CVEs

These are the five CVEs with the highest CVSS scores for bbraun, sorted by severity first and recency.

All CVEs for bbraun

CVE-2023-0888 bbraun vulnerability CVSS: 0 13 Mar 2023, 09:15 UTC

An improper neutralization of directives in dynamically evaluated code vulnerability in the WiFi Battery embedded web server in versions L90/U70 and L92/U92 can be used to gain administrative access to the WiFi communication module. An authenticated user, having access to both the medical device WiFi network (such as a biomedical engineering staff member) and the specific B.Braun Battery Pack SP with WiFi web server credentials, could get administrative (root) access on the infusion pump communication module. This could be used as a vector to start further attacks

CVE-2020-25168 bbraun vulnerability CVSS: 2.1 14 Apr 2022, 21:15 UTC

Hard-coded credentials in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 enable attackers with command line access to access the device’s Wi-Fi module.

CVE-2020-25166 bbraun vulnerability CVSS: 7.5 14 Apr 2022, 21:15 UTC

An improper verification of the cryptographic signature of firmware updates of the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers to generate valid firmware updates with arbitrary content that can be used to tamper with devices.

CVE-2020-25164 bbraun vulnerability CVSS: 5.0 14 Apr 2022, 21:15 UTC

A vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers to recover user credentials of the administrative interface.

CVE-2020-25162 bbraun vulnerability CVSS: 7.8 14 Apr 2022, 21:15 UTC

A XPath injection vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows unauthenticated remote attackers to access sensitive information and escalate privileges.

CVE-2020-25160 bbraun vulnerability CVSS: 4.6 14 Apr 2022, 21:15 UTC

Improper access controls in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 enables attackers to extract and tamper with the devices network configuration.

CVE-2020-25158 bbraun vulnerability CVSS: 4.3 14 Apr 2022, 21:15 UTC

A reflected cross-site scripting (XSS) vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows remote attackers to inject arbitrary web script or HTML into various locations.

CVE-2020-25156 bbraun vulnerability CVSS: 9.0 14 Apr 2022, 21:15 UTC

Active debug code in the B. Braun Melsungen AG SpaceCom Version L8/U61, and the Data module compactplus Versions A10 and A11 and earlier enables attackers in possession of cryptographic material to access the device as root.

CVE-2020-25154 bbraun vulnerability CVSS: 5.8 14 Apr 2022, 21:15 UTC

An open redirect vulnerability in the administrative interface of the B. Braun Melsungen AG SpaceCom device Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers to redirect users to malicious websites.

CVE-2020-25152 bbraun vulnerability CVSS: 5.8 14 Apr 2022, 21:15 UTC

A session fixation vulnerability in the B. Braun Melsungen AG SpaceCom administrative interface Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows remote attackers to hijack web sessions and escalate privileges.

CVE-2020-25150 bbraun vulnerability CVSS: 9.0 14 Apr 2022, 21:15 UTC

A relative path traversal attack in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers with service user privileges to upload arbitrary files. By uploading a specially crafted tar file an attacker can execute arbitrary commands.

CVE-2020-16238 bbraun vulnerability CVSS: 7.2 14 Apr 2022, 21:15 UTC

A vulnerability in the configuration import mechanism of the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers with command line access to the underlying Linux system to escalate privileges to the root user.

CVE-2021-33886 bbraun vulnerability CVSS: 5.8 25 Aug 2021, 12:15 UTC

An improper sanitization of input vulnerability in B. Braun SpaceCom2 prior to 012U000062 allows a remote unauthenticated attacker to gain user-level command-line access by passing a raw external string straight through to printf statements. The attacker is required to be on the same network as the device.

CVE-2021-33885 bbraun vulnerability CVSS: 10.0 25 Aug 2021, 12:15 UTC

An Insufficient Verification of Data Authenticity vulnerability in B. Braun SpaceCom2 prior to 012U000062 allows a remote unauthenticated attacker to send the device malicious data that will be used in place of the correct data. This results in full system command access and execution because of the lack of cryptographic signatures on critical data sets.

CVE-2021-33884 bbraun vulnerability CVSS: 5.0 25 Aug 2021, 12:15 UTC

An Unrestricted Upload of File with Dangerous Type vulnerability in B. Braun SpaceCom2 prior to 012U000062 allows remote attackers to upload any files to the /tmp directory of the device through the webpage API. This can result in critical files being overwritten.

CVE-2021-33883 bbraun vulnerability CVSS: 5.0 25 Aug 2021, 12:15 UTC

A Cleartext Transmission of Sensitive Information vulnerability in B. Braun SpaceCom2 prior to 012U000062 allows a remote attacker to obtain sensitive information by snooping on the network traffic. The exposed data includes critical values for a pump's internal configuration.

CVE-2021-33882 bbraun vulnerability CVSS: 5.0 25 Aug 2021, 12:15 UTC

A Missing Authentication for Critical Function vulnerability in B. Braun SpaceCom2 prior to 012U000062 allows a remote attacker to reconfigure the device from an unknown source because of lack of authentication on proprietary networking commands.

CVE-2020-25174 bbraun vulnerability CVSS: 6.9 06 Nov 2020, 17:15 UTC

A DLL hijacking vulnerability in the B. Braun OnlineSuite Version AP 3.0 and earlier allows local attackers to execute code on the system as a high privileged user.

CVE-2020-25172 bbraun vulnerability CVSS: 7.5 06 Nov 2020, 17:15 UTC

A relative path traversal attack in the B. Braun OnlineSuite Version AP 3.0 and earlier allows unauthenticated attackers to upload or download arbitrary files.

CVE-2020-25170 bbraun vulnerability CVSS: 6.8 06 Nov 2020, 17:15 UTC

An Excel Macro Injection vulnerability exists in the export feature in the B. Braun OnlineSuite Version AP 3.0 and earlier via multiple input fields that are mishandled in an Excel export.

CVE-2017-6018 bbraun vulnerability CVSS: 5.8 30 Jun 2017, 03:29 UTC

An open redirect issue was discovered in B. Braun Medical SpaceCom module, which is integrated into the SpaceStation docking station: SpaceStation with SpaceCom module (integrated as part number 8713142U), software versions prior to Version 012U000040, and SpaceStation (part number 8713140U) with installed SpaceCom module (part number 8713160U), software versions prior to Version 012U000040. The web server of the affected product accepts untrusted input which could allow attackers to redirect the request to an unintended URL contained within untrusted input.