Focus on abb vulnerabilities and metrics.
Last updated: 08 Mar 2025, 23:25 UTC
This page consolidates all known Common Vulnerabilities and Exposures (CVEs) associated with abb. We track both calendar-based metrics (using fixed periods) and rolling metrics (using gliding windows) to give you a comprehensive view of security trends and risk evolution. Use these insights to assess risk and plan your patching strategy.
For a broader perspective on cybersecurity threats, explore the comprehensive list of CVEs by vendor and product. Stay updated on critical vulnerabilities affecting major software and hardware providers.
Total abb CVEs: 111
Earliest CVE date: 29 Sep 2008, 17:17 UTC
Latest CVE date: 15 Jul 2024, 12:15 UTC
Latest CVE reference: CVE-2024-5402
30-day Count (Rolling): 0
365-day Count (Rolling): 3
Calendar-based Variation
Calendar-based Variation compares a fixed calendar period (e.g., this month versus the same month last year), while Rolling Growth Rate uses a continuous window (e.g., last 30 days versus the previous 30 days) to capture trends independent of calendar boundaries.
Month Variation (Calendar): 0%
Year Variation (Calendar): -83.33%
Month Growth Rate (30-day Rolling): 0.0%
Year Growth Rate (365-day Rolling): -83.33%
Average CVSS: 4.3
Max CVSS: 10.0
Critical CVEs (≥9): 8
Range | Count |
---|---|
0.0-3.9 | 41 |
4.0-6.9 | 50 |
7.0-8.9 | 17 |
9.0-10.0 | 8 |
These are the five CVEs with the highest CVSS scores for abb, sorted by severity first and recency.
Unquoted Search Path or Element vulnerability in ABB Mint Workbench. A local attacker who successfully exploited this vulnerability could gain elevated privileges by inserting an executable file in the path of the affected service. This issue affects Mint Workbench I versions: from 5866 before 5868.
Unauthorized file access in WEB Server in ABB ASPECT - Enterprise v3.08.01; NEXUS Series v3.08.01 ; MATRIX Series v3.08.01 allows Attacker to execute arbitrary code remotely
Unauthorized file access in WEB Server in ABB ASPECT - Enterprise v3.08.01; NEXUS Series v3.08.01 ; MATRIX Series v3.08.01 allows Attacker to access files unauthorized
ABB is aware of vulnerabilities in the product versions listed below. An update is available that resolves the reported vulnerabilities in the product versions under maintenance. An attacker who successfully exploited one or more of these vulnerabilities could cause the product to stop or make the product inaccessible. Stack-based Buffer Overflow vulnerability in ABB Freelance controllers AC 700F (conroller modules), ABB Freelance controllers AC 900F (controller modules).This issue affects: Freelance controllers AC 700F: from 9.0;0 through V9.2 SP2, through Freelance 2013, through Freelance 2013SP1, through Freelance 2016, through Freelance 2016SP1, through Freelance 2019 , through Freelance 2019 SP1, through Freelance 2019 SP1 FP1; Freelance controllers AC 900F: through Freelance 2013, through Freelance 2013SP1, through Freelance 2016, through Freelance 2016SP1, through Freelance 2019, through Freelance 2019 SP1, through Freelance 2019 SP1 FP1.
ABB is aware of vulnerabilities in the product versions listed below. An update is available that resolves the reported vulnerabilities in the product versions under maintenance. An attacker who successfully exploited one or more of these vulnerabilities could cause the product to stop or make the product inaccessible. Numeric Range Comparison Without Minimum Check vulnerability in ABB Freelance controllers AC 700F (Controller modules), ABB Freelance controllers AC 900F (controller modules).This issue affects: Freelance controllers AC 700F: from 9.0;0 through V9.2 SP2, through Freelance 2013, through Freelance 2013SP1, through Freelance 2016, through Freelance 2016SP1, through Freelance 2019, through Freelance 2019 SP1, through Freelance 2019 SP1 FP1; Freelance controllers AC 900F: Freelance 2013, through Freelance 2013SP1, through Freelance 2016, through Freelance 2016SP1, through Freelance 2019, through Freelance 2019 SP1, through Freelance 2019 SP1 FP1.
A vulnerability was found in AO-OPC server versions mentioned above. As the directory information for the service entry is not enclosed in quotation marks, potential attackers could possibly call up another application than the AO-OPC server by starting the service. The service might be started with system user privileges which could cause a shift in user access privileges. It is unlikely to exploit the vulnerability in well maintained Windows installations since the attacker would need write access to system folders. An update is available that resolves the vulnerability found during an internal review in the product AO-OPC = 3.2.1
A vulnerability exists by allowing low-privileged users to read and update the data in various directories used by the Zenon system. An attacker could exploit the vulnerability by using specially crafted programs to exploit the vulnerabilities by allowing them to run on the zenon installed hosts. This issue affects ABB Ability™ zenon: from 11 build through 11 build 106404.
A vulnerability exists by allowing low-privileged users to read and update the data in various directories used by the Zenon system. An attacker could exploit the vulnerability by using specially crafted programs to exploit the vulnerabilities by allowing them to run on the zenon installed hosts. This issue affects ABB Ability™ zenon: from 11 build through 11 build 106404.
A vulnerability exists by allowing low-privileged users to read and update the data in various directories used by the Zenon system. An attacker could exploit the vulnerability by using specially crafted programs to exploit the vulnerabilities by allowing them to run on the zenon installed hosts. This issue affects ABB Ability™ zenon: from 11 build through 11 build 106404.
A vulnerability exists by allowing low-privileged users to read and update the data in various directories used by the Zenon system. An attacker could exploit the vulnerability by using specially crafted programs to exploit the vulnerabilities by allowing them to run on the zenon installed hosts. This issue affects ABB Ability™ zenon: from 11 build through 11 build 106404.
Sensitive Cookie Without 'HttpOnly' Flag vulnerability in ABB REX640 PCL1 (firmware modules), ABB REX640 PCL2 (Firmware modules), ABB REX640 PCL3 (firmware modules) allows Cross-Site Scripting (XSS).This issue affects REX640 PCL1: from 1.0;0 before 1.0.8; REX640 PCL2: from 1.0;0 before 1.1.4; REX640 PCL3: from 1.0;0 before 1.2.1.
Improper Input Validation vulnerability in ABB Ltd. ASPECT®-Enterprise on ASPECT®-Enterprise, Linux (2CQG103201S3021, 2CQG103202S3021, 2CQG103203S3021, 2CQG103204S3021 modules), ABB Ltd. NEXUS Series on NEXUS Series, Linux (2CQG100102R2021, 2CQG100104R2021, 2CQG100105R2021, 2CQG100106R2021, 2CQG100110R2021, 2CQG100112R2021, 2CQG100103R2021, 2CQG100107R2021, 2CQG100108R2021, 2CQG100109R2021, 2CQG100111R2021, 2CQG100113R2021 modules), ABB Ltd. MATRIX Series on MATRIX Series, Linux (2CQG100102R1021, 2CQG100103R1021, 2CQG100104R1021, 2CQG100105R1021, 2CQG100106R1021 modules) allows Command Injection.This issue affects ASPECT®-Enterprise: from 3.0;0 before 3.07.0; NEXUS Series: from 3.0;0 before 3.07.0; MATRIX Series: from 3.0;0 before 3.07.1.
Improper Privilege Management vulnerability in ABB Ltd. ASPECT®-Enterprise on ASPECT®-Enterprise, Linux (2CQG103201S3021, 2CQG103202S3021, 2CQG103203S3021, 2CQG103204S3021 modules), ABB Ltd. NEXUS Series on NEXUS Series, Linux (2CQG100102R2021, 2CQG100104R2021, 2CQG100105R2021, 2CQG100106R2021, 2CQG100110R2021, 2CQG100112R2021, 2CQG100103R2021, 2CQG100107R2021, 2CQG100108R2021, 2CQG100109R2021, 2CQG100111R2021, 2CQG100113R2021 modules), ABB Ltd. MATRIX Series on MATRIX Series, Linux (2CQG100102R1021, 2CQG100103R1021, 2CQG100104R1021, 2CQG100105R1021, 2CQG100106R1021 modules) allows Privilege Escalation.This issue affects ASPECT®-Enterprise: from 3.0;0 before 3.07.01; NEXUS Series: from 3.0;0 before 3.07.01; MATRIX Series: from 3.0;0 before 3.07.01.
Insertion of Sensitive Information into Log File vulnerability in ABB QCS 800xA, ABB QCS AC450, ABB Platform Engineering Tools. An attacker, who already has local access to the QCS nodes, could successfully obtain the password for a system user account. Using this information, the attacker could have the potential to exploit this vulnerability to gain control of system nodes. This issue affects QCS 800xA: from 1.0;0 through 6.1SP2; QCS AC450: from 1.0;0 through 5.1SP2; Platform Engineering Tools: from 1.0:0 through 2.3.0.
Cleartext Transmission of Sensitive Information vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (CE) (Terra AC MID), ABB Terra AC wallbox (CE) Terra AC Juno CE, ABB Terra AC wallbox (CE) Terra AC PTB, ABB Terra AC wallbox (CE) Symbiosis, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): from 1.0;0 through 1.5.5; Terra AC wallbox (UL32A) : from 1.0;0 through 1.6.5; Terra AC wallbox (CE) (Terra AC MID): from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC Juno CE: from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC PTB : from 1.0;0 through 1.5.25; Terra AC wallbox (CE) Symbiosis: from 1.0;0 through 1.2.7; Terra AC wallbox (JP): from 1.0;0 through 1.6.5.
Improper Authentication vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (CE) (Terra AC MID), ABB Terra AC wallbox (CE) Terra AC Juno CE, ABB Terra AC wallbox (CE) Terra AC PTB, ABB Terra AC wallbox (CE) Symbiosis, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): from 1.0;0 through 1.5.5; Terra AC wallbox (UL32A) : from 1.0;0 through 1.6.5; Terra AC wallbox (CE) (Terra AC MID): from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC Juno CE: from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC PTB : from 1.0;0 through 1.5.25; Terra AC wallbox (CE) Symbiosis: from 1.0;0 through 1.2.7; Terra AC wallbox (JP): from 1.0;0 through 1.6.5.
Insecure Storage of Sensitive Information vulnerability in ABB My Control System (on-premise) allows an attacker who successfully exploited this vulnerability to gain access to the secure application data or take control of the application. Of the services that make up the My Control System (on-premise) application, the following ones are affected by this vulnerability: User Interface System Monitoring1 Asset Inventory This issue affects My Control System (on-premise): from 5.0;0 through 5.13.
Improper Input Validation vulnerability in ABB AC500 V2 PM5xx allows Client-Server Protocol Manipulation.This issue affects AC500 V2: from 2.0.0 before 2.8.6.
Exposure of Sensitive Information to an Unauthorized Actor vulnerability in ABB Flow-X firmware on Flow-X embedded hardware (web service modules) allows Footprinting.This issue affects Flow-X: before 4.0.
Use of Default Password vulnerability in ABB RCCMD on Windows, Linux, MacOS allows Try Common or Default Usernames and Passwords.This issue affects RCCMD: before 4.40 230207.
Use of Insufficiently Random Values vulnerability in ABB Pulsar Plus System Controller NE843_S, ABB Infinity DC Power Plant.This issue affects Pulsar Plus System Controller NE843_S : comcode 150042936; Infinity DC Power Plant: H5692448 G104 G842 G224L G630-4 G451C(2) G461(2) – comcode 150047415.
Improper Authentication vulnerability in ABB Symphony Plus S+ Operations.This issue affects Symphony Plus S+ Operations: from 2.X through 2.1 SP2, 2.2, from 3.X through 3.3 SP1, 3.3 SP2.
Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1, ABB Relion protection relays - 620 series IEC/CN 2.0, ABB Relion protection relays - 620 series IEC/CN 2.0 FP1, ABB Relion protection relays - REX640 PCL1, ABB Relion protection relays - REX640 PCL2, ABB Relion protection relays - REX640 PCL3, ABB Relion protection relays - RER615, ABB Remote Monitoring and Control - REC615, ABB Merging Unit- SMU615 allows Communication Channel Manipulation.This issue affects Relion protection relays - 611 series: from 1.0.0 before 2.0.3; Relion protection relays - 615 series IEC 4.0 FP1: from 4.1.0 before 4.1.9; Relion protection relays - 615 series CN 4.0 FP1: from 4.1.0 before 4.1.8; Relion protection relays - 615 series IEC 5.0: from 5.0.0 before 5.0.12; Relion protection relays - 615 series IEC 5.0 FP1: from 5.1.0 before 5.1.20; Relion protection relays - 620 series IEC/CN 2.0: from 2.0.0 before 2.0.11; Relion protection relays - 620 series IEC/CN 2.0 FP1: from 2.1.0 before 2.1.15; Relion protection relays - REX640 PCL1: from 1.0.0 before 1.0.8; Relion protection relays - REX640 PCL2: from 1.1.0 before 1.1.4; Relion protection relays - REX640 PCL3: from 1.2.0 before 1.2.1; Relion protection relays - RER615: from 2.0.0 before 2.0.3; Remote Monitoring and Control - REC615: from 1.0.0 before 2.0.3; Merging Unit- SMU615: from 1.0.0 before 1.0.2.
An issue has been discovered in GitLab CE/EE affecting all versions starting from 15.4 before 15.5.7, all versions starting from 15.6 before 15.6.4, all versions starting from 15.7 before 15.7.2. Due to the improper filtering of query parameters in the wiki changes page, an attacker can execute arbitrary JavaScript on the self-hosted instances running without strict CSP.
Storing Passwords in a Recoverable Format vulnerability in ABB Zenon 8.20 allows an attacker who successfully exploit the vulnerability may add or alter data points and corresponding attributes. Once such engineering data is used the data visualization will be altered for the end user.
Storing Passwords in a Recoverable Format vulnerability in ABB Zenon 8.20 allows an attacker who successfully exploit the vulnerability may add more network clients that may monitor various activities of the Zenon.
Relative Path Traversal vulnerability in ABB Zenon 8.20 allows the user to access files on the Zenon system and user also can add own log messages and e.g., flood the log entries. An attacker who successfully exploit the vulnerability could access the Zenon runtime activities such as the start and stop of various activity and the last error code etc.
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in flow computer and remote controller products of ABB ( RMC-100 (Standard), RMC-100-LITE, XIO, XFCG5 , XRCG5 , uFLOG5 , UDC) allows an attacker who successfully exploited this vulnerability could insert and run arbitrary code in an affected system node.
Incorrect Permission Assignment for Critical Resource vulnerability in ABB REX640 PCL1, REX640 PCL2, REX640 PCL3 allows an authenticated attacker to launch an attack against the user database file and try to take control of an affected system node.
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
Vulnerabilities in the Drive Composer allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Drive Composer installer file allows a low-privileged user to run a "repair" operation on the product.
Vulnerabilities in the Mint WorkBench allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Mint WorkBench installer file allows a low-privileged user to run a "repair" operation on the product
A vulnerability in ABB ARG600 Wireless Gateway series that could allow an attacker to exploit the vulnerability by remotely connecting to the serial port gateway, and/or protocol converter, depending on the configuration.
Improper Input Validation vulnerability in ABB 800xA, Control Software for AC 800M, Control Builder Safe, Compact Product Suite - Control and I/O, ABB Base Software for SoftControl allows an attacker to cause the denial of service.
Improper Input Validation vulnerability in the ABB SPIET800 and PNI800 module allows an attacker to cause the denial of service or make the module unresponsive.
Improper Input Validation vulnerability in the ABB SPIET800 and PNI800 module allows an attacker to cause the denial of service or make the module unresponsive.
Improper Handling of Exceptional Conditions, Improper Check for Unusual or Exceptional Conditions vulnerability in the ABB SPIET800 and PNI800 module that allows an attacker to cause the denial of service or make the module unresponsive.
A certificate validation vulnerability in PCM600 Update Manager allows attacker to get unwanted software packages to be installed on computer which has PCM600 installed.
The vulnerability origins in the commissioning process where an attacker of the ControlTouch can enter a serial number in a specific way to transfer the device virtually into her/his my.busch-jaeger.de or mybuildings.abb.com profile. A successful attacker can observe and control a ControlTouch remotely under very specific circumstances. The issue is fixed in the cloud side of the system. No firmware update is needed for customer products. If a user wants to understand if (s)he is affected, please read the advisory. This issue affects: ABB and Busch-Jaeger, ControlTouch
The vulnerability allows a successful attacker to bypass the integrity check of FW uploaded to the free@home System Access Point.
A vulnerability in Base Software for SoftControl allows an attacker to insert and run arbitrary code in a computer running the affected product. This issue affects: .
The vulnerabilities can be exploited to cause the web visualization component of the PLC to stop and not respond, leading to genuine users losing remote visibility of the PLC state. If a user attempts to login to the PLC while this vulnerability is exploited, the PLC will show an error state and refuse connections to Automation Builder. The execution of the PLC application is not affected by this vulnerability. This issue affects ABB AC500 V2 products with onboard Ethernet.
An unauthenticated specially crafted packet sent by an attacker over the network will cause a denial-of-service (DoS) vulnerability. Vulnerability allows attacker to stop the PLC. After stopping (ERR LED flashing red), physical access to the PLC is required in order to restart the application. This issue affects: ABB AC500 V2 products with onboard Ethernet version 2.8.4 and prior versions.
The affected versions of S+ Operations (version 2.1 SP1 and earlier) used an approach for user authentication which relies on validation at the client node (client-side authentication). This is not as secure as having the server validate a client application before allowing a connection. Therefore, if the network communication or endpoints for these applications are not protected, unauthorized actors can bypass authentication and make unauthorized connections to the server application.
In S+ Operations and S+ Historian, the passwords of internal users (not Windows Users) are encrypted but improperly stored in a database.
A S+ Operations and S+ Historian service is subject to a DoS by special crafted messages. An attacker might use this flaw to make it crash or even execute arbitrary code on the machine where the service is hosted.
An authenticated user might execute malicious code under the user context and take control of the system. S+ Operations or S+ Historian database is affected by multiple vulnerabilities such as the possibility to allow remote authenticated users to gain high privileges.
Vulnerabilities in the S+ Operations and S+ Historian web applications can lead to a possible code execution and privilege escalation, redirect the user somewhere else or download unwanted data.
In Symphony Plus Operations and Symphony Plus Historian, some services can be vulnerable to privilege escalation attacks. An unprivileged (but authenticated) user could execute arbitrary code and result in privilege escalation, depending on the user that the service runs as.
In S+ Operations and S+ History, it is possible that an unauthenticated user could inject values to the Operations History server (or standalone S+ History server) and ultimately write values to the controlled process.
In S+ Operations and S+ Historian, not all client commands correctly check user permission as expected. Authenticated but Unauthorized remote users could execute a Denial-of-Service (DoS) attack, execute arbitrary code, or obtain more privilege than intended on the machines.
In S+ Operations and S+ Historian, a successful SQL injection exploit can read sensitive data from the database, modify database data (Insert/Update/Delete), execute administration operations on the database (such as shutdown the DBMS), recover the content of a given file present on the DBMS file system and in some cases issue commands to the operating system. This can lead to a loss of confidentiality and data integrity or even affect the product behavior and its availability.
IRC5 exposes an ftp server (port 21). Upon attempting to gain access you are challenged with a request of username and password, however you can input whatever you like. As long as the field isn't empty it will be accepted.
The IRC5 family with UAS service enabled comes by default with credentials that can be found on publicly available manuals. ABB considers this a well documented functionality that helps customer set up however, out of our research, we found multiple production systems running these exact default credentials and consider thereby this an exposure that should be mitigated. Moreover, future deployments should consider that these defaults should be forbidden (user should be forced to change them).
Insecure storage of sensitive information in ABB Device Library Wizard versions 6.0.X, 6.0.3.1 and 6.0.3.2 allows unauthenticated low privilege user to read file that contains confidential data
Insufficient protection of the inter-process communication functions in ABB System 800xA Information Management (all published versions) enables an attacker authenticated on the local system to inject data, affecting the runtime values to be stored in the archive, or making Information Management history services unavailable.
Insufficient protection of the inter-process communication functions in ABB System 800xA Batch Management (all published versions) enables an attacker authenticated on the local system to inject data, affecting User Interface update during batch execution and/or compare/printing functionalities.
Insufficient protection of the inter-process communication functions in ABB System 800xA Base (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling.
Insufficient protection of the inter-process communication functions in ABB System 800xA RNRP (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling.
Insufficient protection of the inter-process communication functions in ABB System 800xA for MOD 300 (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash.
Insufficient protection of the inter-process communication functions in ABB System 800xA for DCI (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash.
For ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, confidential data is written in an unprotected file. An attacker who successfully exploited this vulnerability could take full control of the computer.
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5. an XML External Entity Injection vulnerability exists that allows an attacker to read or call arbitrary files from the license server and/or from the network and also block the license handling.
Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl (all published versions) enables an attacker authenticated on the local system to inject data, affecting the online view of runtime data shown in Control Builder.
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5, a weakness in validation of input exists that allows an attacker to alter licenses assigned to the system nodes by sending specially crafted messages to the CLS web service.
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5, a weakness in validation of input exists that allows an attacker to block license handling by sending specially crafted messages to the CLS web service.
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, weak file permissions allow an authenticated attacker to block the license handling, escalate his/her privileges and execute arbitrary code.
Insufficient folder permissions used by system functions in ABB System 800xA Base (version 6.1 and earlier) allow low privileged users to read, modify, add and delete system and application files. An authenticated attacker who successfully exploit the vulnerabilities could escalate his/her privileges, cause system functions to stop and to corrupt user applications.
Insufficient folder permissions used by system functions in ABB System 800xA products OPCServer for AC800M (versions 6.0 and earlier) and Control Builder M Professional, MMSServer for AC800M, Base Software for SoftControl (version 6.1 and earlier) allow low privileged users to read, modify, add and delete system and application files. An authenticated attacker who successfully exploited the vulnerabilities could escalate his/her privileges, cause system functions to stop and to corrupt user applications.
UPS Adapter CS141 before 1.90 allows Directory Traversal. An attacker with Admin or Engineer login credentials could exploit the vulnerability by manipulating variables that reference files and by doing this achieve access to files and directories outside the web root folder. An attacker may access arbitrary files and directories stored in the file system, but integrity of the files are not jeopardized as attacker have read access rights only.
The installations for ABB System 800xA Information Manager versions 5.1, 6.0 to 6.0.3.2 and 6.1 wrongly contain an auxiliary component. An attacker is able to use this for an XSS-like attack to an authenticated local user, which might lead to execution of arbitrary code.
Weak Registry permissions in ABB System 800xA Base allow low privileged users to read and modify registry settings related to control system functionality, allowing an authenticated attacker to cause system functions to stop or malfunction.
The Configuration pages in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway for user profiles and services transfer the password in plaintext (although hidden when displayed).
Improper implementation of Access Control in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows an unauthorized user to access data marked as restricted, such as viewing or editing user profiles and application settings.
The backup function in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway saves the current settings and configuration of the application, including credentials of existing user accounts and other configuration's credentials in plaintext.
The web server in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows access to different endpoints of the application without authenticating by accessing a specific uniform resource locator (URL) , violating the access-control (ACL) rules. This issue allows obtaining sensitive information that may aid in further attacks and privilege escalation.
ABB CP651 HMI products revision BSP UN30 v1.76 and prior implement hidden administrative accounts that are used during the provisioning phase of the HMI interface.
The HMISimulator component of ABB PB610 Panel Builder 600 uses the readFile/writeFile interface to manipulate the work file. Path configuration in PB610 HMISimulator versions 2.8.0.424 and earlier potentially allows access to files outside of the working directory, thus potentially supporting unauthorized file access.
Path settings in HMIStudio component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier accept DLLs outside of the program directory, potentially allowing an attacker with access to the local file system the execution of code in the application’s context.
The HMISimulator component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier fails to validate the content-length field for HTTP requests, exposing HMISimulator to denial of service via crafted HTTP requests manipulating the content-length setting.
Due to a lack of file length check, the HMIStudio component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier crashes when trying to load an empty *.JPR application file. An attacker with access to the file system might be able to cause application malfunction such as denial of service.
In all versions of ABB Power Generation Information Manager (PGIM) and Plant Connect, the affected product is vulnerable to authentication bypass, which may allow an attacker to remotely bypass authentication and extract credentials from the affected device.
The ABB HMI components implement hidden administrative accounts that are used during the provisioning phase of the HMI interface. These credentials allow the provisioning tool "Panel Builder 600" to flash a new interface and Tags (MODBUS coils) mapping to the HMI. These credentials are the idal123 password for the IdalMaster account, and the exor password for the exor account. These credentials are used over both HTTP(S) and FTP. There is no option to disable or change these undocumented credentials. An attacker can use these credentials to login to ABB HMI to read/write HMI configuration files and also to reset the device. This affects ABB CP635 HMI, CP600 HMIClient, Panel Builder 600, IDAL FTP server, IDAL HTTP server, and multiple other HMI components.
In the ABB IDAL FTP server, an authenticated attacker can traverse to arbitrary directories on the hard disk with "CWD ../" and then use the FTP server functionality to download and upload files. An unauthenticated attacker can take advantage of the hardcoded or default credential pair exor/exor to become an authenticated attacker.
The ABB IDAL HTTP server CGI interface contains a URL that allows an unauthenticated attacker to bypass authentication and gain access to privileged functions. Specifically, /cgi/loginDefaultUser creates a session in an authenticated state and returns the session ID along with what may be the username and cleartext password of the user. An attacker can then supply an IDALToken value in a cookie, which will allow them to perform privileged operations such as restarting the service with /cgi/restart. A GET request to /cgi/loginDefaultUser may result in "1 #S_OK IDALToken=532c8632b86694f0232a68a0897a145c admin admin" or a similar response.
The ABB IDAL HTTP server mishandles format strings in a username or cookie during the authentication process. Attempting to authenticate with the username %25s%25p%25x%25n will crash the server. Sending %08x.AAAA.%08x.%08x will log memory content from the stack.
The ABB IDAL FTP server is vulnerable to a buffer overflow when a long string is sent by an authenticated attacker. This overflow is handled, but terminates the process. An authenticated attacker can send a FTP command string of 472 bytes or more to overflow a buffer, causing an exception that terminates the server.
The ABB CP635 HMI uses two different transmission methods to upgrade its firmware and its software components: "Utilization of USB/SD Card to flash the device" and "Remote provisioning process via ABB Panel Builder 600 over FTP." Neither of these transmission methods implements any form of encryption or authenticity checks against the new firmware HMI software binary files.
The ABB IDAL HTTP server is vulnerable to a buffer overflow when a long Host header is sent in a web request. The Host header value overflows a buffer and overwrites a Structured Exception Handler (SEH) address. An unauthenticated attacker can submit a Host header value of 2047 bytes or more to overflow the buffer and overwrite the SEH address, which can then be leveraged to execute attacker-controlled code on the server.
The ABB IDAL FTP server mishandles format strings in a username during the authentication process. Attempting to authenticate with the username %s%p%x%d will crash the server. Sending %08x.AAAA.%08x.%08x will log memory content from the stack.
ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets.
The TextEditor 2.0 in ABB CP400 Panel Builder versions 2.0.7.05 and earlier contain a vulnerability in the file parser of the Text Editor wherein the application doesn't properly prevent the insertion of specially crafted files which could allow arbitrary code execution.
The product CMS-770 (Software Versions 1.7.1 and prior)is vulnerable that an attacker can read sensitive configuration files by bypassing the user authentication mechanism.
The product M2M ETHERNET (FW Versions 2.22 and prior, ETH-FW Versions 1.01 and prior) is vulnerable in that an attacker can upload a malicious language file by bypassing the user authentication mechanism.
Pluto Safety PLC Gateway Ethernet devices in ABB GATE-E1 and GATE-E2 all versions allows an unauthenticated attacker using the administrative web interface to insert an HTML/Javascript payload into any of the device properties, which may allow an attacker to display/execute the payload in a visitor browser.
Pluto Safety PLC Gateway Ethernet devices ABB GATE-E1 and GATE-E2 all versions do not allow authentication to be configured on administrative telnet or web interfaces, which could enable various effects vectors, including conducting device resets, reading or modifying registers, and changing configuration settings such as IP addresses.
ABB Panel Builder 800 all versions has an improper input validation vulnerability which may allow an attacker to insert and run arbitrary code on a computer where the affected product is used.
In ABB IP GATEWAY 3.39 and prior, some configuration files contain passwords stored in plain-text, which may allow an attacker to gain unauthorized access.
In ABB IP GATEWAY 3.39 and prior, by accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access the configuration files and application pages without authentication.
In ABB IP GATEWAY 3.39 and prior, the web server does not sufficiently verify that a request was performed by the authenticated user, which may allow an attacker to launch a request impersonating that user.
In ABB SREA-01 revisions A, B, C: application versions up to 3.31.5, and SREA-50 revision A: application versions up to 3.32.8, an attacker may access internal files of ABB SREA-01 and SREA-50 legacy remote monitoring tools without any authorization over the network using a HTTP request which refers to files using ../../ relative paths. Once the internal password file is retrieved, the password hash can be identified using a brute force attack. There is also an exploit allowing running of commands after authorization.
An Information Exposure issue was discovered in ABB netCADOPS Web Application Version 3.4 and prior, netCADOPS Web Application Version 7.1 and prior, netCADOPS Web Application Version 7.2x and prior, netCADOPS Web Application Version 8.0 and prior, and netCADOPS Web Application Version 8.1 and prior. A vulnerability exists in the password entry section of netCADOPS Web Application that may expose critical database information.
An Improper Authentication issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access internal information about status and connected devices without authenticating.
A Permissions, Privileges, and Access Controls issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. The web application does not properly restrict privileges of the Guest account. A malicious user may be able to gain access to configuration information that should be restricted.
ABB PCM600 before 2.7 improperly stores PCM600 authentication credentials, which allows local users to obtain sensitive information via unspecified vectors.
ABB PCM600 before 2.7 improperly stores OPC Server IEC61850 passwords in unspecified temporary circumstances, which allows local users to obtain sensitive information via unknown vectors.
ABB PCM600 before 2.7 improperly stores the main application password after a password change, which allows local users to obtain sensitive information via unspecified vectors.
ABB PCM600 before 2.7 uses an improper hash algorithm for the main application password, which makes it easier for local users to obtain sensitive cleartext information by leveraging read access to the ACTConfig configuration file.
Untrusted search path vulnerability in ABB Panel Builder 800 5.1 allows local users to gain privileges via a Trojan horse DLL in the current working directory.
Untrusted search path vulnerability in ABB RobotStudio 5.6x before 5.61.02 and Test Signal Viewer 1.5 allows local users to gain privileges via a Trojan horse DLL that is accessed as a result of incorrect DLL configuration by an optional installation program.
Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlier, the Data Analysis component in ABB DataManager 1 through 6.3.6, and other products allow remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method in the (1) CWNumEdit, (2) CWGraph, (3) CWBoolean, (4) CWSlide, or (5) CWKnob ActiveX control, in conjunction with file content in the (a) Caption or (b) FormatString property value.
Multiple stack-based buffer overflows in (1) COM and (2) ActiveX controls in ABB WebWare Server, WebWare SDK, Interlink Module, S4 OPC Server, QuickTeach, RobotStudio S4, and RobotStudio Lite allow remote attackers to execute arbitrary code via crafted input data.
Multiple stack-based buffer overflows in RobNetScanHost.exe in ABB Robot Communications Runtime before 5.14.02, as used in ABB Interlink Module, IRC5 OPC Server, PC SDK, PickMaster 3 and 5, RobView 5, RobotStudio, WebWare SDK, and WebWare Server, allow remote attackers to execute arbitrary code via a crafted (1) 0xA or (2) 0xE Netscan packet.
Buffer overflow in x87 before 3.5.5 in ABB Process Communication Unit 400 (PCU400) 4.4 through 4.6 allows remote attackers to execute arbitrary code via a crafted packet using the (1) IEC60870-5-101 or (2) IEC60870-5-104 communication protocol to the X87 web interface.