CVE-2026-71255
Vulnerability Scoring
Cybersecurity professionals consider CVE-2026-71255 an immediate threat requiring urgent mitigation.
Cybersecurity professionals consider CVE-2026-71255 an immediate threat requiring urgent mitigation.
Status: Received on 05 Aug 2026, 12:18 UTC
Published on: 05 Aug 2026, 12:18 UTC
CVSS Release: version 3
309f9ea4-e3e9-4c6c-b79d-e8eb01244f2c
Secondary
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H
CVE-2026-71255: nanoMODBUS through v1.23.0 contains an out-of-bounds write in the Modbus client-side recv_read_device_identification_res() function (FC 0x2B/MEI 0x0E, Read Device Identification) in nanomodbus.c. The server-supplied object_length field (0-246) is validated only against the remaining PDU size (res_size_left) and is never validated against the caller-supplied buffers_length parameter. After copying data with strncpy(buffers_out[buf_index], str, buffers_length), the code unconditionally writes a NUL terminator at buffers_out[buf_index][object_length]. When a malicious or compromised Modbus server sends a response with object_length greater than or equal to the client's buffers_length, this NUL write lands past the end of the caller-provided buffer, corrupting adjacent stack or heap memory on the client.
The exploitability of CVE-2026-71255 depends on two key factors: attack complexity (the level of effort required to execute an exploit) and privileges required (the access level an attacker needs).
With low attack complexity and no required privileges, CVE-2026-71255 is an easy target for cybercriminals. Organizations should prioritize immediate mitigation measures to prevent unauthorized access and data breaches.
A lower complexity and fewer privilege requirements make exploitation easier. Security teams should evaluate these aspects to determine the urgency of mitigation strategies, such as patch management and access control policies.
Attack Complexity (AC) measures the difficulty in executing an exploit. A high AC means that specific conditions must be met, making an attack more challenging, while a low AC means the vulnerability can be exploited with minimal effort.
Privileges Required (PR) determine the level of system access necessary for an attack. Vulnerabilities requiring no privileges are more accessible to attackers, whereas high privilege requirements limit exploitation to authorized users with elevated access.
Above is the CVSS Sub-score Breakdown for CVE-2026-71255, illustrating how Base, Impact, and Exploitability factors combine to form the overall severity rating. A higher sub-score typically indicates a more severe or easier-to-exploit vulnerability.
Below is the Impact Analysis for CVE-2026-71255, showing how Confidentiality, Integrity, and Availability might be affected if the vulnerability is exploited. Higher values usually signal greater potential damage.
Stay updated with real-time CVE vulnerabilities and take action to secure your systems. Enhance your cybersecurity posture with the latest threat intelligence and mitigation techniques. Develop the skills necessary to defend against CVEs and secure critical infrastructures. Join the top cybersecurity professionals safeguarding today's infrastructures.