CVE-2026-4642 Vulnerability Analysis & Exploit Details

CVE-2026-4642
Vulnerability Scoring

6.6
/10
High Risk

If left unpatched, CVE-2026-4642 could lead to major system disruptions or data loss.

Attack Complexity Details

  • Attack Complexity: High
    Exploits require significant effort and special conditions.
  • Attack Vector: Network
    Vulnerability is exploitable over a network without physical access.
  • Privileges Required: High
    High-level privileges are required for exploitation.
  • Scope: Unchanged
    Exploit remains within the originally vulnerable component.
  • User Interaction: None
    No user interaction is necessary for exploitation.

CVE-2026-4642 Details

Status: Received on 27 Nov 2026, 15:17 UTC

Published on: 27 Nov 2026, 15:17 UTC

CVSS Release: version 3

CVSS3 Source

cybersecurity@ch.abb.com

CVSS3 Type

Secondary

CVSS3 Vector

CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H

CVE-2026-4642 Vulnerability Summary

CVE-2026-4642: Incorrect Authorization vulnerability in ABB Relion Protection Relays REX610, ABB Relion Protection Relays RE_611 IEC/CN, ABB Relion Protection Relays RBX615, ABB Relion Protection Relays REF615 ANSI, ABB Relion Protection Relays REF615R ANSI, ABB Relion Protection Relays RER615, ABB Relion Protection Relays REC615, ABB Relion Protection Relays REX615, ABB Relion Protection Relays 615 series IEC, ABB Relion Protection Relays 615 series CN, ABB Relion Protection Relays 615 series ANSI, ABB Relion Protection Relays RER620 ANSI, ABB Relion Protection Relays 620 series ANSI, ABB Relion Protection Relays 620 series IEC/CN, and ABB Substation Merging Unit SMU615. This issue affects Relion Protection Relays REX610: 1.0, 1.1, and 1.2; Relion Protection Relays RE_611 IEC/CN: 1.0 and 2.0; Relion Protection Relays RBX615: 1.0 and 2.0; Relion Protection Relays REF615 ANSI: 4.1; Relion Protection Relays REF615R ANSI: 4.0 and 4.0 FP1; Relion Protection Relays RER615: 1.0, 1.1, and 2.0; Relion Protection Relays REC615: 1.0, 1.1, and 2.0; Relion Protection Relays REX615: PCL1 (6.0); Relion Protection Relays 615 series IEC: 3.1, 4.0, 4.0 FP1, 5.0, and 5.0 FP1; Relion Protection Relays 615 series CN: 3.1, 4.1, and 5.0 FP1; Relion Protection Relays 615 series ANSI: 4.0, 4.0 FP1, 4.0 FP2, and 5.0 FP1; Relion Protection Relays RER620 ANSI: 1.1, 1.2, and 1.3; Relion Protection Relays 620 series ANSI: 2.0 and 2.0 FP1; Relion Protection Relays 620 series IEC/CN: 2.0 and 2.0 FP1; Substation Merging Unit SMU615: 1.0.

Assessing the Risk of CVE-2026-4642

Access Complexity Graph

The exploitability of CVE-2026-4642 depends on two key factors: attack complexity (the level of effort required to execute an exploit) and privileges required (the access level an attacker needs).

Exploitability Analysis for CVE-2026-4642

The exploitability of CVE-2026-4642 is influenced by multiple factors. Security teams should analyze system configurations and apply appropriate countermeasures to mitigate threats.

Understanding AC and PR

A lower complexity and fewer privilege requirements make exploitation easier. Security teams should evaluate these aspects to determine the urgency of mitigation strategies, such as patch management and access control policies.

Attack Complexity (AC) measures the difficulty in executing an exploit. A high AC means that specific conditions must be met, making an attack more challenging, while a low AC means the vulnerability can be exploited with minimal effort.

Privileges Required (PR) determine the level of system access necessary for an attack. Vulnerabilities requiring no privileges are more accessible to attackers, whereas high privilege requirements limit exploitation to authorized users with elevated access.

CVSS Score Breakdown Chart

Above is the CVSS Sub-score Breakdown for CVE-2026-4642, illustrating how Base, Impact, and Exploitability factors combine to form the overall severity rating. A higher sub-score typically indicates a more severe or easier-to-exploit vulnerability.

CIA Impact Analysis

Below is the Impact Analysis for CVE-2026-4642, showing how Confidentiality, Integrity, and Availability might be affected if the vulnerability is exploited. Higher values usually signal greater potential damage.

  • Confidentiality: High
    Exploiting CVE-2026-4642 can result in unauthorized access to sensitive data, severely compromising data privacy.
  • Integrity: High
    CVE-2026-4642 could allow unauthorized modifications to data, potentially affecting system reliability and trust.
  • Availability: High
    CVE-2026-4642 can disrupt system operations, potentially causing complete denial of service (DoS).

CVE-2026-4642 References

External References

CWE Common Weakness Enumeration

CWE-863

Protect Your Infrastructure against CVE-2026-4642: Combat Critical CVE Threats

Stay updated with real-time CVE vulnerabilities and take action to secure your systems. Enhance your cybersecurity posture with the latest threat intelligence and mitigation techniques. Develop the skills necessary to defend against CVEs and secure critical infrastructures. Join the top cybersecurity professionals safeguarding today's infrastructures.

Other 5 Recently Published CVEs Vulnerabilities

  • CVE-2026-85252 – A SQL Injection vulnerability in the Revenue Reports API in Google Cloud Apigee Edge Monetization versions prior to 2026-07-16 (Public Cloud) and O...
  • CVE-2026-80508 – Dell Secure Connect Gateway - Virtual Edition, versions prior to 5.36.00.16, contains an Authentication Bypass by Spoofing vulnerability. An unauth...
  • CVE-2026-80507 – Dell Secure Connect Gateway - Virtual Edition, versions prior to 5.36.00.16, contains a Heap-based Buffer Overflow vulnerability. An unauthenticate...
  • CVE-2026-80506 – Dell Secure Connect Gateway - Virtual Edition, versions prior to 5.36.00.16, contains a Use of Hard-coded Cryptographic Key vulnerability. A low pr...
  • CVE-2026-80505 – Dell Secure Connect Gateway - Virtual Edition, versions prior to 5.36.00.16, contains an Improper Access Control vulnerability. A low privileged lo...