CVE-2026-118608 Vulnerability Analysis & Exploit Details

CVE-2026-118608
Vulnerability Scoring

3.5
/10
Moderate Risk

Exploiting CVE-2026-118608 requires specific conditions, leading to a moderate security impact.

Attack Complexity Details

  • Attack Complexity: Low
    Exploits can be performed without significant complexity or special conditions.
  • Attack Vector: Adjacent_network
    Attack Vector Under Analysis
  • Privileges Required: None
    No privileges are required for exploitation.
  • Scope: Unchanged
    Exploit remains within the originally vulnerable component.
  • User Interaction: Required
    User interaction is necessary for successful exploitation.

CVE-2026-118608 Details

Status: Received on 28 Oct 2026, 17:18 UTC

Published on: 28 Oct 2026, 17:18 UTC

CVSS Release: version 3

CVSS3 Source

zdi-disclosures@trendmicro.com

CVSS3 Type

Secondary

CVSS3 Vector

CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N

CVE-2026-118608 Vulnerability Summary

CVE-2026-118608: Alpine iLX-F511 libanwbtstack.so prh_rfcomm_cc_process_test Out-Of-Bounds Read Information Disclosure Vulnerability. This vulnerability allows network-adjacent attackers to disclose sensitive information on affected installations of Alpine iLX-F511 devices. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability. The specific flaw exists within the prh_rfcomm_cc_process_test function. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of root. Was ZDI-CAN-29018.

Assessing the Risk of CVE-2026-118608

Access Complexity Graph

The exploitability of CVE-2026-118608 depends on two key factors: attack complexity (the level of effort required to execute an exploit) and privileges required (the access level an attacker needs).

Exploitability Analysis for CVE-2026-118608

With low attack complexity and no required privileges, CVE-2026-118608 is an easy target for cybercriminals. Organizations should prioritize immediate mitigation measures to prevent unauthorized access and data breaches.

Understanding AC and PR

A lower complexity and fewer privilege requirements make exploitation easier. Security teams should evaluate these aspects to determine the urgency of mitigation strategies, such as patch management and access control policies.

Attack Complexity (AC) measures the difficulty in executing an exploit. A high AC means that specific conditions must be met, making an attack more challenging, while a low AC means the vulnerability can be exploited with minimal effort.

Privileges Required (PR) determine the level of system access necessary for an attack. Vulnerabilities requiring no privileges are more accessible to attackers, whereas high privilege requirements limit exploitation to authorized users with elevated access.

CVSS Score Breakdown Chart

Above is the CVSS Sub-score Breakdown for CVE-2026-118608, illustrating how Base, Impact, and Exploitability factors combine to form the overall severity rating. A higher sub-score typically indicates a more severe or easier-to-exploit vulnerability.

CIA Impact Analysis

Below is the Impact Analysis for CVE-2026-118608, showing how Confidentiality, Integrity, and Availability might be affected if the vulnerability is exploited. Higher values usually signal greater potential damage.

  • Confidentiality: Low
    CVE-2026-118608 could lead to minor leaks of non-critical information without major privacy breaches.
  • Integrity: None
    CVE-2026-118608 poses no threat to data integrity.
  • Availability: None
    CVE-2026-118608 does not impact system availability.

CVE-2026-118608 References

External References

CWE Common Weakness Enumeration

CWE-125

CAPEC Common Attack Pattern Enumeration and Classification

  • Overread Buffers CAPEC-540 An adversary attacks a target by providing input that causes an application to read beyond the boundary of a defined buffer. This typically occurs when a value influencing where to start or stop reading is set to reflect positions outside of the valid memory location of the buffer. This type of attack may result in exposure of sensitive information, a system crash, or arbitrary code execution.

Protect Your Infrastructure against CVE-2026-118608: Combat Critical CVE Threats

Stay updated with real-time CVE vulnerabilities and take action to secure your systems. Enhance your cybersecurity posture with the latest threat intelligence and mitigation techniques. Develop the skills necessary to defend against CVEs and secure critical infrastructures. Join the top cybersecurity professionals safeguarding today's infrastructures.

Other 5 Recently Published CVEs Vulnerabilities

  • CVE-2026-84725 – when EAP runs with -secmgr, the openjdk-orb's JDKBridge honours attacker-supplied CDR codebase URLs during object unmarshalling on :3528, allowing ...
  • CVE-2026-79656 – A user with read access to Grafana's server logs, or to a log store they are shipped to, can recover the OAuth and OIDC access, refresh and ID toke...
  • CVE-2026-58458 – Don't Starve Together (Steam AppID 322330) through build 747465 contains a memory-corruption vulnerability in the native persistent-string decoder ...
  • CVE-2026-118250 – Highcharts JS is a JavaScript charting library based on SVG. From 6.1.0 until 11.4.9, 12.6.1, and 3.1.0, Highcharts follows dot-separated series.ke...
  • CVE-2026-118249 – Highcharts JS is a JavaScript charting library based on SVG. From 13.0.0 until 13.1.0, Highcharts builds series data columns by using point option ...