CVE-2026-10660
Vulnerability Scoring
If left unpatched, CVE-2026-10660 could lead to major system disruptions or data loss.
If left unpatched, CVE-2026-10660 could lead to major system disruptions or data loss.
Status: Received on 11 Jul 2026, 17:16 UTC
Published on: 11 Jul 2026, 17:16 UTC
CVSS Release: version 3
vulnerabilities@zephyrproject.org
Secondary
CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:H
CVE-2026-10660: The Bluetooth BAP Broadcast Assistant GATT client in subsys/bluetooth/audio/bap_broadcast_assistant.c reassembled remote Broadcast Receive State data into a single file-static net_buf_simple (att_buf, BT_ATT_MAX_ATTRIBUTE_LEN = 512 bytes) shared by all connection instances, while the BUSY flag, long-read handle, and reset/offset state were per-connection. When the device acts as a Broadcast Assistant connected to multiple Scan Delegator peripherals, notification and long-read callbacks from different connections interleave on the shared buffer: the append in notify_handler (net_buf_simple_add_mem at the not-busy branch) performs no tailroom check, so receive-state notifications from two or more delegators accumulate on the same 512-byte buffer and, with a sufficiently large configured ATT MTU (BT_L2CAP_TX_MTU up to 2000) and two-to-three concurrent connections, write past the buffer into adjacent .bss (net_buf_simple_add only asserts in debug builds). Even below the overflow threshold, one connection's net_buf_simple_reset zeroes the shared length while another connection's reassembly and GATT read offset are in flight, mixing one peer's data into another's parse. A malicious or compromised Scan Delegator (or two colluding peers) over BLE can trigger this, causing out-of-bounds writes (memory corruption / denial of service) and cross-connection data corruption. The fix moves the buffer into the per-connection instance struct so each connection reassembles into its own buffer. Affects Zephyr releases shipping the Broadcast Assistant with the shared buffer, including v4.4.0 and earlier.
The exploitability of CVE-2026-10660 depends on two key factors: attack complexity (the level of effort required to execute an exploit) and privileges required (the access level an attacker needs).
CVE-2026-10660 presents a challenge to exploit due to its high attack complexity, but the absence of privilege requirements still makes it a viable target for skilled attackers. A thorough security review is advised.
A lower complexity and fewer privilege requirements make exploitation easier. Security teams should evaluate these aspects to determine the urgency of mitigation strategies, such as patch management and access control policies.
Attack Complexity (AC) measures the difficulty in executing an exploit. A high AC means that specific conditions must be met, making an attack more challenging, while a low AC means the vulnerability can be exploited with minimal effort.
Privileges Required (PR) determine the level of system access necessary for an attack. Vulnerabilities requiring no privileges are more accessible to attackers, whereas high privilege requirements limit exploitation to authorized users with elevated access.
Above is the CVSS Sub-score Breakdown for CVE-2026-10660, illustrating how Base, Impact, and Exploitability factors combine to form the overall severity rating. A higher sub-score typically indicates a more severe or easier-to-exploit vulnerability.
Below is the Impact Analysis for CVE-2026-10660, showing how Confidentiality, Integrity, and Availability might be affected if the vulnerability is exploited. Higher values usually signal greater potential damage.
Stay updated with real-time CVE vulnerabilities and take action to secure your systems. Enhance your cybersecurity posture with the latest threat intelligence and mitigation techniques. Develop the skills necessary to defend against CVEs and secure critical infrastructures. Join the top cybersecurity professionals safeguarding today's infrastructures.