CVE-2025-53843 Vulnerability Analysis & Exploit Details

CVE-2025-53843
Vulnerability Scoring

7.5
/10
Very High Risk

Highly exploitable, CVE-2025-53843 poses a critical security risk that could lead to severe breaches.

Attack Complexity Details

  • Attack Complexity: High
    Exploits require significant effort and special conditions.
  • Attack Vector: Network
    Vulnerability is exploitable over a network without physical access.
  • Privileges Required: Low
    Some privileges are necessary to exploit the vulnerability.
  • Scope: Unchanged
    Exploit remains within the originally vulnerable component.
  • User Interaction: None
    No user interaction is necessary for exploitation.

CVE-2025-53843 Details

Status: Received on 18 Nov 2025, 17:16 UTC

Published on: 18 Nov 2025, 17:16 UTC

CVSS Release: version 3

CVSS3 Source

psirt@fortinet.com

CVSS3 Type

Secondary

CVSS3 Vector

CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H

CVE-2025-53843 Vulnerability Summary

CVE-2025-53843: A stack-based buffer overflow in Fortinet FortiOS 7.6.0 through 7.6.3, FortiOS 7.4.0 through 7.4.8, FortiOS 7.2 all versions, FortiOS 7.0 all versions, FortiOS 6.4 all versions allows attacker to execute unauthorized code or commands via specially crafted packets

Assessing the Risk of CVE-2025-53843

Access Complexity Graph

The exploitability of CVE-2025-53843 depends on two key factors: attack complexity (the level of effort required to execute an exploit) and privileges required (the access level an attacker needs).

Exploitability Analysis for CVE-2025-53843

This vulnerability, CVE-2025-53843, requires a high level of attack complexity and low privileges, making it difficult but not impossible to exploit. Organizations should ensure robust security configurations to mitigate risks.

Understanding AC and PR

A lower complexity and fewer privilege requirements make exploitation easier. Security teams should evaluate these aspects to determine the urgency of mitigation strategies, such as patch management and access control policies.

Attack Complexity (AC) measures the difficulty in executing an exploit. A high AC means that specific conditions must be met, making an attack more challenging, while a low AC means the vulnerability can be exploited with minimal effort.

Privileges Required (PR) determine the level of system access necessary for an attack. Vulnerabilities requiring no privileges are more accessible to attackers, whereas high privilege requirements limit exploitation to authorized users with elevated access.

CVSS Score Breakdown Chart

Above is the CVSS Sub-score Breakdown for CVE-2025-53843, illustrating how Base, Impact, and Exploitability factors combine to form the overall severity rating. A higher sub-score typically indicates a more severe or easier-to-exploit vulnerability.

CIA Impact Analysis

Below is the Impact Analysis for CVE-2025-53843, showing how Confidentiality, Integrity, and Availability might be affected if the vulnerability is exploited. Higher values usually signal greater potential damage.

  • Confidentiality: High
    Exploiting CVE-2025-53843 can result in unauthorized access to sensitive data, severely compromising data privacy.
  • Integrity: High
    CVE-2025-53843 could allow unauthorized modifications to data, potentially affecting system reliability and trust.
  • Availability: High
    CVE-2025-53843 can disrupt system operations, potentially causing complete denial of service (DoS).

CVE-2025-53843 References

External References

CWE Common Weakness Enumeration

CWE-121

Protect Your Infrastructure against CVE-2025-53843: Combat Critical CVE Threats

Stay updated with real-time CVE vulnerabilities and take action to secure your systems. Enhance your cybersecurity posture with the latest threat intelligence and mitigation techniques. Develop the skills necessary to defend against CVEs and secure critical infrastructures. Join the top cybersecurity professionals safeguarding today's infrastructures.

Other 5 Recently Published CVEs Vulnerabilities

  • CVE-2025-63228 – The Mozart FM Transmitter web management interface on version WEBMOZZI-00287, contains an unauthenticated file upload vulnerability in the /upload_...
  • CVE-2025-63227 – The Mozart FM Transmitter web management interface on version WEBMOZZI-00287, contains an unrestricted file upload vulnerability in the /patch.php ...
  • CVE-2025-63226 – The Sencore SMP100 SMP Media Platform (firmware versions V4.2.160, V60.1.4, V60.1.29) is vulnerable to session hijacking due to improper session ma...
  • CVE-2025-37162 – A vulnerability in the command line interface of affected devices could allow an authenticated remote attacker to conduct a command injection attac...
  • CVE-2025-37161 – A vulnerability in the web-based management interface of affected products could allow an unauthenticated remote attacker to cause a denial of serv...