CVE-2025-4909 Vulnerability Analysis & Exploit Details

CVE-2025-4909
Vulnerability Scoring

7.3
/10
Very High Risk

Highly exploitable, CVE-2025-4909 poses a critical security risk that could lead to severe breaches.

Attack Complexity Details

  • Attack Complexity: Low
    Exploits can be performed without significant complexity or special conditions.
  • Attack Vector: Network
    Vulnerability is exploitable over a network without physical access.
  • Privileges Required: None
    No privileges are required for exploitation.
  • Scope: Unchanged
    Exploit remains within the originally vulnerable component.
  • User Interaction: None
    No user interaction is necessary for exploitation.

CVE-2025-4909 Details

Status: Received on 19 May 2025, 04:15 UTC

Published on: 19 May 2025, 04:15 UTC

CVSS Release: version 3

CVSS3 Source

cna@vuldb.com

CVSS3 Type

Primary

CVSS3 Vector

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L

CVE-2025-4909 Vulnerability Summary

CVE-2025-4909: A vulnerability classified as critical was found in SourceCodester Client Database Management System 1.0. This vulnerability affects unknown code. The manipulation leads to exposure of information through directory listing. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Assessing the Risk of CVE-2025-4909

Access Complexity Graph

The exploitability of CVE-2025-4909 depends on two key factors: attack complexity (the level of effort required to execute an exploit) and privileges required (the access level an attacker needs).

Exploitability Analysis for CVE-2025-4909

With low attack complexity and no required privileges, CVE-2025-4909 is an easy target for cybercriminals. Organizations should prioritize immediate mitigation measures to prevent unauthorized access and data breaches.

Understanding AC and PR

A lower complexity and fewer privilege requirements make exploitation easier. Security teams should evaluate these aspects to determine the urgency of mitigation strategies, such as patch management and access control policies.

Attack Complexity (AC) measures the difficulty in executing an exploit. A high AC means that specific conditions must be met, making an attack more challenging, while a low AC means the vulnerability can be exploited with minimal effort.

Privileges Required (PR) determine the level of system access necessary for an attack. Vulnerabilities requiring no privileges are more accessible to attackers, whereas high privilege requirements limit exploitation to authorized users with elevated access.

CVSS Score Breakdown Chart

Above is the CVSS Sub-score Breakdown for CVE-2025-4909, illustrating how Base, Impact, and Exploitability factors combine to form the overall severity rating. A higher sub-score typically indicates a more severe or easier-to-exploit vulnerability.

CIA Impact Analysis

Below is the Impact Analysis for CVE-2025-4909, showing how Confidentiality, Integrity, and Availability might be affected if the vulnerability is exploited. Higher values usually signal greater potential damage.

  • Confidentiality: Low
    CVE-2025-4909 could lead to minor leaks of non-critical information without major privacy breaches.
  • Integrity: Low
    Exploiting CVE-2025-4909 may cause minor changes to data without severely impacting its accuracy.
  • Availability: Low
    CVE-2025-4909 may slightly degrade system performance without fully affecting service availability.

CVE-2025-4909 References

External References

CWE Common Weakness Enumeration

CWE-552

CAPEC Common Attack Pattern Enumeration and Classification

  • Collect Data from Common Resource Locations CAPEC-150 An adversary exploits well-known locations for resources for the purposes of undermining the security of the target. In many, if not most systems, files and resources are organized in a default tree structure. This can be useful for adversaries because they often know where to look for resources or files that are necessary for attacks. Even when the precise location of a targeted resource may not be known, naming conventions may indicate a small area of the target machine's file tree where the resources are typically located. For example, configuration files are normally stored in the /etc director on Unix systems. Adversaries can take advantage of this to commit other types of attacks.
  • Probe System Files CAPEC-639 An adversary obtains unauthorized information due to improperly protected files. If an application stores sensitive information in a file that is not protected by proper access control, then an adversary can access the file and search for sensitive information.

Protect Your Infrastructure against CVE-2025-4909: Combat Critical CVE Threats

Stay updated with real-time CVE vulnerabilities and take action to secure your systems. Enhance your cybersecurity posture with the latest threat intelligence and mitigation techniques. Develop the skills necessary to defend against CVEs and secure critical infrastructures. Join the top cybersecurity professionals safeguarding today's infrastructures.

Other 5 Recently Published CVEs Vulnerabilities

  • CVE-2025-4914 – A vulnerability was found in PHPGurukul Auto Taxi Stand Management System 1.0. It has been classified as critical. This affects an unknown part of ...
  • CVE-2025-4913 – A vulnerability was found in PHPGurukul Auto Taxi Stand Management System 1.0 and classified as critical. Affected by this issue is some unknown fu...
  • CVE-2025-4477 – The ThreatSonar Anti-Ransomware from TeamT5 has a Privilege Escalation vulnerability, allowing remote attackers with intermediate privileges to esc...
  • CVE-2025-2561 – The Ninja Forms WordPress plugin before 3.10.1 does not sanitise and escape some of its settings, which could allow high privilege users such as a...
  • CVE-2025-2560 – The Ninja Forms WordPress plugin before 3.10.1 does not sanitise and escape some of its settings, which could allow high privilege users such as a...