CVE-2024-50560 Vulnerability Analysis & Exploit Details

CVE-2024-50560
Vulnerability Scoring

3.1
/10
Moderate Risk

Exploiting CVE-2024-50560 requires specific conditions, leading to a moderate security impact.

Attack Complexity Details

  • Attack Complexity: High
    Exploits require significant effort and special conditions.
  • Attack Vector: Network
    Vulnerability is exploitable over a network without physical access.
  • Privileges Required: Low
    Some privileges are necessary to exploit the vulnerability.
  • Scope: Unchanged
    Exploit remains within the originally vulnerable component.
  • User Interaction: None
    No user interaction is necessary for exploitation.

CVE-2024-50560 Details

Status: Modified

Last updated: 🕚 11 Feb 2025, 11:15 UTC
Originally published on: 🕐 12 Nov 2024, 13:15 UTC

Time between publication and last update: 90 days

CVSS Release: version 3

CVSS3 Source

productcert@siemens.com

CVSS3 Type

Secondary

CVSS3 Vector

CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:L/A:N

CVE-2024-50560 Vulnerability Summary

CVE-2024-50560: A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions < V8.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.2), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions < V8.2), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions < V8.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.2), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions < V8.2), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions < V8.2), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions < V8.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions < V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions < V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V3.0.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions < V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V3.0.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions < V3.0.0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions < V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V3.0.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions < V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V3.0.0). Affected devices truncates usernames longer than 15 characters when accessed via SSH or Telnet. This could allow an attacker to compromise system integrity.

Assessing the Risk of CVE-2024-50560

Access Complexity Graph

The exploitability of CVE-2024-50560 depends on two key factors: attack complexity (the level of effort required to execute an exploit) and privileges required (the access level an attacker needs).

Exploitability Analysis for CVE-2024-50560

This vulnerability, CVE-2024-50560, requires a high level of attack complexity and low privileges, making it difficult but not impossible to exploit. Organizations should ensure robust security configurations to mitigate risks.

Understanding AC and PR

A lower complexity and fewer privilege requirements make exploitation easier. Security teams should evaluate these aspects to determine the urgency of mitigation strategies, such as patch management and access control policies.

Attack Complexity (AC) measures the difficulty in executing an exploit. A high AC means that specific conditions must be met, making an attack more challenging, while a low AC means the vulnerability can be exploited with minimal effort.

Privileges Required (PR) determine the level of system access necessary for an attack. Vulnerabilities requiring no privileges are more accessible to attackers, whereas high privilege requirements limit exploitation to authorized users with elevated access.

CVSS Score Breakdown Chart

Above is the CVSS Sub-score Breakdown for CVE-2024-50560, illustrating how Base, Impact, and Exploitability factors combine to form the overall severity rating. A higher sub-score typically indicates a more severe or easier-to-exploit vulnerability.

CIA Impact Analysis

Below is the Impact Analysis for CVE-2024-50560, showing how Confidentiality, Integrity, and Availability might be affected if the vulnerability is exploited. Higher values usually signal greater potential damage.

  • Confidentiality: None
    CVE-2024-50560 has no significant impact on data confidentiality.
  • Integrity: Low
    Exploiting CVE-2024-50560 may cause minor changes to data without severely impacting its accuracy.
  • Availability: None
    CVE-2024-50560 does not impact system availability.

Exploit Prediction Scoring System (EPSS)

The EPSS score estimates the probability that this vulnerability will be exploited in the near future.

EPSS Score: 0.045% (probability of exploit)

EPSS Percentile: 16.83% (lower percentile = lower relative risk)
This vulnerability is less risky than approximately 83.17% of others.

CVE-2024-50560 References

External References

CWE Common Weakness Enumeration

NVD-CWE-noinfo

Vulnerable Configurations

  • cpe:2.3:o:siemens:ruggedcom_rm1224_lte\(4g\)_eu_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:ruggedcom_rm1224_lte\(4g\)_eu_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:ruggedcom_rm1224_lte\(4g\)_eu_firmware:8.1:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:ruggedcom_rm1224_lte\(4g\)_eu_firmware:8.1:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:ruggedcom_rm1224_lte\(4g\)_eu:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:ruggedcom_rm1224_lte\(4g\)_eu:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:ruggedcom_rm1224_lte\(4g\)_nam_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:ruggedcom_rm1224_lte\(4g\)_nam_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:ruggedcom_rm1224_lte\(4g\)_nam_firmware:8.1:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:ruggedcom_rm1224_lte\(4g\)_nam_firmware:8.1:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:ruggedcom_rm1224_lte\(4g\)_nam:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:ruggedcom_rm1224_lte\(4g\)_nam:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_m804pb_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m804pb_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_m804pb_firmware:7.1.2:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m804pb_firmware:7.1.2:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_m804pb_firmware:8.1:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m804pb_firmware:8.1:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_m804pb:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_m804pb:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_m812-1_\(annex_a\)_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m812-1_\(annex_a\)_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_m812-1_\(annex_a\)_firmware:8.1:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m812-1_\(annex_a\)_firmware:8.1:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_m812-1_\(annex_a\):-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_m812-1_\(annex_a\):-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_m812-1_\(annex_b\)_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m812-1_\(annex_b\)_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_m812-1_\(annex_b\)_firmware:8.1:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m812-1_\(annex_b\)_firmware:8.1:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_m812-1_\(annex_b\):-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_m812-1_\(annex_b\):-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_m816-1_\(annex_a\)_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m816-1_\(annex_a\)_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_m816-1_\(annex_a\)_firmware:8.1:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m816-1_\(annex_a\)_firmware:8.1:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_m816-1_\(annex_a\):-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_m816-1_\(annex_a\):-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_m816-1_\(annex_b\)_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m816-1_\(annex_b\)_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_m816-1_\(annex_b\)_firmware:8.1:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m816-1_\(annex_b\)_firmware:8.1:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_m816-1_\(annex_b\):-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_m816-1_\(annex_b\):-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_m826-2_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m826-2_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_m826-2_firmware:7.1.2:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m826-2_firmware:7.1.2:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_m826-2:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_m826-2:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_m874-2_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m874-2_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_m874-2_firmware:7.1.2:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m874-2_firmware:7.1.2:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_m874-2_firmware:8.1:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m874-2_firmware:8.1:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_m874-2:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_m874-2:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_m874-3_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m874-3_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_m874-3_firmware:7.1.2:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m874-3_firmware:7.1.2:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_m874-3_firmware:8.1:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m874-3_firmware:8.1:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_m874-3:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_m874-3:-:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_m874-3_\(cn\):-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_m874-3_\(cn\):-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_m876-3_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m876-3_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_m876-3_firmware:7.1.2:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m876-3_firmware:7.1.2:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_m876-3_firmware:8.1:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m876-3_firmware:8.1:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_m876-3:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_m876-3:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_m876-3_\(rok\)_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m876-3_\(rok\)_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_m876-3_\(rok\)_firmware:8.1:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m876-3_\(rok\)_firmware:8.1:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_m876-3_\(rok\):-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_m876-3_\(rok\):-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_m876-4_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m876-4_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_m876-4_firmware:7.1.2:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m876-4_firmware:7.1.2:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_m876-4_firmware:8.1:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m876-4_firmware:8.1:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_m876-4:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_m876-4:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_m876-4_\(eu\)_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m876-4_\(eu\)_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_m876-4_\(eu\)_firmware:8.1:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m876-4_\(eu\)_firmware:8.1:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_m876-4_\(eu\):-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_m876-4_\(eu\):-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_m876-4_\(nam\)_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m876-4_\(nam\)_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_m876-4_\(nam\)_firmware:8.1:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m876-4_\(nam\)_firmware:8.1:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_m876-4_\(nam\):-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_m876-4_\(nam\):-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_mum853-1_\(a1\)_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_mum853-1_\(a1\)_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_mum853-1_\(a1\)_firmware:8.1:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_mum853-1_\(a1\)_firmware:8.1:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_mum853-1_\(a1\):-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_mum853-1_\(a1\):-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_mum853-1_\(b1\)_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_mum853-1_\(b1\)_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_mum853-1_\(b1\)_firmware:8.1:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_mum853-1_\(b1\)_firmware:8.1:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_mum853-1_\(b1\):-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_mum853-1_\(b1\):-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_mum853-1_\(eu\)_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_mum853-1_\(eu\)_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_mum853-1_\(eu\)_firmware:8.1:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_mum853-1_\(eu\)_firmware:8.1:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_mum853-1_\(eu\):-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_mum853-1_\(eu\):-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_mum856-1_\(a1\)_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_mum856-1_\(a1\)_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_mum856-1_\(a1\)_firmware:8.1:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_mum856-1_\(a1\)_firmware:8.1:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_mum856-1_\(a1\):-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_mum856-1_\(a1\):-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_mum856-1_\(b1\)_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_mum856-1_\(b1\)_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_mum856-1_\(b1\)_firmware:8.1:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_mum856-1_\(b1\)_firmware:8.1:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_mum856-1_\(b1\):-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_mum856-1_\(b1\):-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_mum856-1_\(cn\)_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_mum856-1_\(cn\)_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_mum856-1_\(cn\)_firmware:8.1:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_mum856-1_\(cn\)_firmware:8.1:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_mum856-1_\(cn\):-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_mum856-1_\(cn\):-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_mum856-1_\(eu\)_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_mum856-1_\(eu\)_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_mum856-1_\(eu\)_firmware:8.1:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_mum856-1_\(eu\)_firmware:8.1:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_mum856-1_\(eu\):-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_mum856-1_\(eu\):-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_mum856-1_\(row\)_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_mum856-1_\(row\)_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_mum856-1_\(row\)_firmware:8.1:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_mum856-1_\(row\)_firmware:8.1:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_mum856-1_\(row\):-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_mum856-1_\(row\):-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_s615_eec_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_s615_eec_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_s615_eec:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_s615_eec:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_s615_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_s615_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_s615_firmware:4.01:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_s615_firmware:4.01:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_s615_firmware:4.3:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_s615_firmware:4.3:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_s615_firmware:4.03:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_s615_firmware:4.03:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_s615_firmware:4.6:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_s615_firmware:4.6:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_s615_firmware:5.0:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_s615_firmware:5.0:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_s615_firmware:6.1:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_s615_firmware:6.1:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_s615_firmware:6.1.2:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_s615_firmware:6.1.2:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_s615_firmware:6.2:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_s615_firmware:6.2:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_s615_firmware:6.3:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_s615_firmware:6.3:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_s615_firmware:7.1.2:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_s615_firmware:7.1.2:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*

Protect Your Infrastructure against CVE-2024-50560: Combat Critical CVE Threats

Stay updated with real-time CVE vulnerabilities and take action to secure your systems. Enhance your cybersecurity posture with the latest threat intelligence and mitigation techniques. Develop the skills necessary to defend against CVEs and secure critical infrastructures. Join the top cybersecurity professionals safeguarding today's infrastructures.

Other 5 Recently Published CVEs Vulnerabilities

  • CVE-2025-3809 – The Debug Log Manager plugin for WordPress is vulnerable to Stored Cross-Site Scripting via the auto-refresh debug log in all versions up to, and i...
  • CVE-2025-2111 – The Insert Headers And Footers plugin for WordPress is vulnerable to Cross-Site Request Forgery in all versions up to, and including, 3.1.1. This i...
  • CVE-2024-13926 – The WP-Syntax WordPress plugin through 1.2 does not properly handle input, allowing an attacker to create a post containing a large number of tags,...
  • CVE-2025-3103 – The CLEVER - HTML5 Radio Player With History - Shoutcast and Icecast - Elementor Widget Addon plugin for WordPress is vulnerable to arbitrary file ...
  • CVE-2025-3275 – The Themesflat Addons For Elementor plugin for WordPress is vulnerable to Stored Cross-Site Scripting via the TF E Slider widget in all versions up...