CVE-2022-26647 Vulnerability Analysis & Exploit Details

CVE-2022-26647
Vulnerability Scoring

8.8
/10
Severe Risk

Cybersecurity professionals consider CVE-2022-26647 an immediate threat requiring urgent mitigation.

Attack Complexity Details

  • Attack Complexity: Low
    Exploits can be performed without significant complexity or special conditions.
  • Attack Vector: Network
    Vulnerability is exploitable over a network without physical access.
  • Privileges Required: None
    No privileges are required for exploitation.
  • Scope: Unchanged
    Exploit remains within the originally vulnerable component.
  • User Interaction: Required
    User interaction is necessary for successful exploitation.

CVE-2022-26647 Details

Status: Modified

Last updated: 🕡 21 Nov 2024, 06:54 UTC
Originally published on: 🕙 12 Jul 2022, 10:15 UTC

Time between publication and last update: 862 days

CVSS Release: version 3

CVSS3 Source

productcert@siemens.com

CVSS3 Type

Secondary

CVSS3 Vector

CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

CVE-2022-26647 Vulnerability Summary

CVE-2022-26647: A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT PRO (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2P IRT (All versions < V5.5.2), SCALANCE X202-2P IRT PRO (All versions < V5.5.2), SCALANCE X204-2 (All versions < V5.2.6), SCALANCE X204-2FM (All versions < V5.2.6), SCALANCE X204-2LD (All versions < V5.2.6), SCALANCE X204-2LD TS (All versions < V5.2.6), SCALANCE X204-2TS (All versions < V5.2.6), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT PRO (All versions < V5.5.2), SCALANCE X206-1 (All versions < V5.2.6), SCALANCE X206-1LD (All versions < V5.2.6), SCALANCE X208 (All versions < V5.2.6), SCALANCE X208PRO (All versions < V5.2.6), SCALANCE X212-2 (All versions < V5.2.6), SCALANCE X212-2LD (All versions < V5.2.6), SCALANCE X216 (All versions < V5.2.6), SCALANCE X224 (All versions < V5.2.6), SCALANCE XF201-3P IRT (All versions < V5.5.2), SCALANCE XF202-2P IRT (All versions < V5.5.2), SCALANCE XF204 (All versions < V5.2.6), SCALANCE XF204-2 (All versions < V5.2.6), SCALANCE XF204-2BA IRT (All versions < V5.5.2), SCALANCE XF204IRT (All versions < V5.5.2), SCALANCE XF206-1 (All versions < V5.2.6), SCALANCE XF208 (All versions < V5.2.6). The webserver of affected devices calculates session ids and nonces in an insecure manner. This could allow an unauthenticated remote attacker to brute-force session ids and hijack existing sessions.

Assessing the Risk of CVE-2022-26647

Access Complexity Graph

The exploitability of CVE-2022-26647 depends on two key factors: attack complexity (the level of effort required to execute an exploit) and privileges required (the access level an attacker needs).

Exploitability Analysis for CVE-2022-26647

With low attack complexity and no required privileges, CVE-2022-26647 is an easy target for cybercriminals. Organizations should prioritize immediate mitigation measures to prevent unauthorized access and data breaches.

Understanding AC and PR

A lower complexity and fewer privilege requirements make exploitation easier. Security teams should evaluate these aspects to determine the urgency of mitigation strategies, such as patch management and access control policies.

Attack Complexity (AC) measures the difficulty in executing an exploit. A high AC means that specific conditions must be met, making an attack more challenging, while a low AC means the vulnerability can be exploited with minimal effort.

Privileges Required (PR) determine the level of system access necessary for an attack. Vulnerabilities requiring no privileges are more accessible to attackers, whereas high privilege requirements limit exploitation to authorized users with elevated access.

CVSS Score Breakdown Chart

Above is the CVSS Sub-score Breakdown for CVE-2022-26647, illustrating how Base, Impact, and Exploitability factors combine to form the overall severity rating. A higher sub-score typically indicates a more severe or easier-to-exploit vulnerability.

CIA Impact Analysis

Below is the Impact Analysis for CVE-2022-26647, showing how Confidentiality, Integrity, and Availability might be affected if the vulnerability is exploited. Higher values usually signal greater potential damage.

  • Confidentiality: High
    Exploiting CVE-2022-26647 can result in unauthorized access to sensitive data, severely compromising data privacy.
  • Integrity: High
    CVE-2022-26647 could allow unauthorized modifications to data, potentially affecting system reliability and trust.
  • Availability: High
    CVE-2022-26647 can disrupt system operations, potentially causing complete denial of service (DoS).

Exploit Prediction Scoring System (EPSS)

The EPSS score estimates the probability that this vulnerability will be exploited in the near future.

EPSS Score: 0.051% (probability of exploit)

EPSS Percentile: 23.11% (lower percentile = lower relative risk)
This vulnerability is less risky than approximately 76.89% of others.

CVE-2022-26647 References

External References

CWE Common Weakness Enumeration

CWE-330

CAPEC Common Attack Pattern Enumeration and Classification

  • Brute Force CAPEC-112 In this attack, some asset (information, functionality, identity, etc.) is protected by a finite secret value. The attacker attempts to gain access to this asset by using trial-and-error to exhaustively explore all the possible secret values in the hope of finding the secret (or a value that is functionally equivalent) that will unlock the asset.
  • Signature Spoofing by Key Recreation CAPEC-485 An attacker obtains an authoritative or reputable signer's private signature key by exploiting a cryptographic weakness in the signature algorithm or pseudorandom number generation and then uses this key to forge signatures from the original signer to mislead a victim into performing actions that benefit the attacker.
  • Session Credential Falsification through Prediction CAPEC-59 This attack targets predictable session ID in order to gain privileges. The attacker can predict the session ID used during a transaction to perform spoofing and session hijacking.

Vulnerable Configurations

  • cpe:2.3:o:siemens:scalance_x200-4p_irt_firmware:*:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x200-4p_irt_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_x200-4p_irt:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_x200-4p_irt:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x201-3p_irt_firmware:*:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x201-3p_irt_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_x201-3p_irt:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_x201-3p_irt:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x201-3p_irt_pro_firmware:*:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x201-3p_irt_pro_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_x201-3p_irt_pro:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_x201-3p_irt_pro:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x202-2irt_firmware:*:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x202-2irt_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_x202-2irt:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_x202-2irt:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x202-2p_irt_firmware:*:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x202-2p_irt_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_x202-2p_irt:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_x202-2p_irt:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x202-2p_irt_pro_firmware:*:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x202-2p_irt_pro_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_x202-2p_irt_pro:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_x202-2p_irt_pro:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x204-2_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x204-2_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x204-2_firmware:5.2.5:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x204-2_firmware:5.2.5:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_x204-2:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_x204-2:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x204-2fm_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x204-2fm_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x204-2fm_firmware:5.2.5:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x204-2fm_firmware:5.2.5:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_x204-2fm:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_x204-2fm:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x204-2ld_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x204-2ld_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x204-2ld_firmware:5.2.5:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x204-2ld_firmware:5.2.5:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_x204-2ld:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_x204-2ld:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x204-2ld_ts_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x204-2ld_ts_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x204-2ld_ts_firmware:5.2.5:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x204-2ld_ts_firmware:5.2.5:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_x204-2ld_ts:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_x204-2ld_ts:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x204-2ts_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x204-2ts_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x204-2ts_firmware:5.2.5:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x204-2ts_firmware:5.2.5:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_x204-2ts:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_x204-2ts:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x204irt_firmware:*:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x204irt_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_x204irt:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_x204irt:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x204irt_pro_firmware:*:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x204irt_pro_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_x204irt_pro:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_x204irt_pro:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x206-1_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x206-1_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x206-1_firmware:5.2.5:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x206-1_firmware:5.2.5:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_x206-1:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_x206-1:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x206-1ld_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x206-1ld_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x206-1ld_firmware:5.2.5:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x206-1ld_firmware:5.2.5:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_x206-1ld:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_x206-1ld:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x208_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x208_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x208_firmware:5.2.5:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x208_firmware:5.2.5:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_x208:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_x208:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x208_pro_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x208_pro_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_x208_pro:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_x208_pro:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x212-2_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x212-2_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x212-2_firmware:5.2.5:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x212-2_firmware:5.2.5:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_x212-2:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_x212-2:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x212-2ld_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x212-2ld_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x212-2ld_firmware:5.2.5:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x212-2ld_firmware:5.2.5:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_x212-2ld:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_x212-2ld:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x216_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x216_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x216_firmware:5.2.5:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x216_firmware:5.2.5:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_x216:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_x216:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x224_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x224_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_x224_firmware:5.2.5:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_x224_firmware:5.2.5:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_x224:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_x224:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_xf201-3p_irt_firmware:*:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_xf201-3p_irt_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_xf201-3p_irt:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_xf201-3p_irt:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_xf202-2p_irt_firmware:*:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_xf202-2p_irt_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_xf202-2p_irt:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_xf202-2p_irt:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_xf204_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_xf204_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_xf204_firmware:5.2.5:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_xf204_firmware:5.2.5:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_xf204:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_xf204:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_xf204-2_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_xf204-2_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_xf204-2_firmware:5.2.5:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_xf204-2_firmware:5.2.5:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_xf204-2:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_xf204-2:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_xf204-2ba_irt_firmware:*:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_xf204-2ba_irt_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_xf204-2ba_irt:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_xf204-2ba_irt:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_xf204irt_firmware:*:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_xf204irt_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_xf204irt:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_xf204irt:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_xf206-1_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_xf206-1_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_xf206-1_firmware:5.2.5:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_xf206-1_firmware:5.2.5:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_xf206-1:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_xf206-1:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_xf208_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_xf208_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:scalance_xf208_firmware:5.2.5:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_xf208_firmware:5.2.5:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:scalance_xf208:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:scalance_xf208:-:*:*:*:*:*:*:*

Protect Your Infrastructure against CVE-2022-26647: Combat Critical CVE Threats

Stay updated with real-time CVE vulnerabilities and take action to secure your systems. Enhance your cybersecurity posture with the latest threat intelligence and mitigation techniques. Develop the skills necessary to defend against CVEs and secure critical infrastructures. Join the top cybersecurity professionals safeguarding today's infrastructures.

Other 5 Recently Published CVEs Vulnerabilities

  • CVE-2025-2129 – A vulnerability was found in Mage AI 0.9.75. It has been classified as problematic. This affects an unknown part. The manipulation leads to insecur...
  • CVE-2025-2127 – A vulnerability was found in JoomlaUX JUX Real Estate 3.4.0 on Joomla. It has been classified as problematic. Affected is an unknown function of th...
  • CVE-2025-2126 – A vulnerability was found in JoomlaUX JUX Real Estate 3.4.0 on Joomla and classified as critical. This issue affects some unknown processing of the...
  • CVE-2025-2125 – A vulnerability has been found in Control iD RH iD 25.2.25.0 and classified as problematic. This vulnerability affects unknown code of the file /v2...
  • CVE-2025-2124 – A vulnerability, which was classified as problematic, was found in Control iD RH iD 25.2.25.0. This affects an unknown part of the file /v2/custome...