CVE-2021-20587 Vulnerability Analysis & Exploit Details

CVE-2021-20587
Vulnerability Scoring

9.8
/10
Critical Risk

As a catastrophic security flaw, CVE-2021-20587 has severe implications, demanding immediate intervention.

Attack Complexity Details

  • Attack Complexity: Low
    Exploits can be performed without significant complexity or special conditions.
  • Attack Vector: Network
    Vulnerability is exploitable over a network without physical access.
  • Privileges Required: None
    No privileges are required for exploitation.
  • Scope: Unchanged
    Exploit remains within the originally vulnerable component.
  • User Interaction: None
    No user interaction is necessary for exploitation.

CVE-2021-20587 Details

Status: Modified

Last updated: 🕠 21 Nov 2024, 05:46 UTC
Originally published on: 🕗 19 Feb 2021, 20:15 UTC

Time between publication and last update: 1370 days

CVSS Release: version 3

CVSS3 Source

nvd@nist.gov

CVSS3 Type

Primary

CVSS3 Vector

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

CVE-2021-20587 Vulnerability Summary

CVE-2021-20587: Heap-based buffer overflow vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) all versions, iQ Monozukuri Process Remote Monitoring (Data Transfer) all versions, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utility all versions, MELSOFT EM Software Development Kit (EM Configurator) versions 1.015R and prior, MELSOFT Navigator versions 2.74C and prior, MH11 SettingTool Version2 versions 2.004E and prior, MI Configurator versions 1.004E and prior, MT Works2 versions 1.167Z and prior, MX Component versions 5.001B and prior, Network Interface Board CC IE Control utility versions 1.29F and prior, Network Interface Board CC IE Field Utility versions 1.16S and prior, Network Interface Board CC-Link Ver.2 Utility versions 1.23Z and prior, Network Interface Board MNETH utility versions 34L and prior, PX Developer versions 1.53F and prior, RT ToolBox2 versions 3.73B and prior, RT ToolBox3 versions 1.82L and prior, Setting/monitoring tools for the C Controller module (SW4PVC-CCPU) versions 4.12N and prior and SLMP Data Collector versions 1.04E and prior) allows a remote unauthenticated attacker to cause a DoS condition of the software products, and possibly to execute a malicious program on the personal computer running the software products although it has not been reproduced, by spoofing MELSEC, GOT or FREQROL and returning crafted reply packets.

Assessing the Risk of CVE-2021-20587

Access Complexity Graph

The exploitability of CVE-2021-20587 depends on two key factors: attack complexity (the level of effort required to execute an exploit) and privileges required (the access level an attacker needs).

Exploitability Analysis for CVE-2021-20587

With low attack complexity and no required privileges, CVE-2021-20587 is an easy target for cybercriminals. Organizations should prioritize immediate mitigation measures to prevent unauthorized access and data breaches.

Understanding AC and PR

A lower complexity and fewer privilege requirements make exploitation easier. Security teams should evaluate these aspects to determine the urgency of mitigation strategies, such as patch management and access control policies.

Attack Complexity (AC) measures the difficulty in executing an exploit. A high AC means that specific conditions must be met, making an attack more challenging, while a low AC means the vulnerability can be exploited with minimal effort.

Privileges Required (PR) determine the level of system access necessary for an attack. Vulnerabilities requiring no privileges are more accessible to attackers, whereas high privilege requirements limit exploitation to authorized users with elevated access.

CVSS Score Breakdown Chart

Above is the CVSS Sub-score Breakdown for CVE-2021-20587, illustrating how Base, Impact, and Exploitability factors combine to form the overall severity rating. A higher sub-score typically indicates a more severe or easier-to-exploit vulnerability.

CIA Impact Analysis

Below is the Impact Analysis for CVE-2021-20587, showing how Confidentiality, Integrity, and Availability might be affected if the vulnerability is exploited. Higher values usually signal greater potential damage.

  • Confidentiality: High
    Exploiting CVE-2021-20587 can result in unauthorized access to sensitive data, severely compromising data privacy.
  • Integrity: High
    CVE-2021-20587 could allow unauthorized modifications to data, potentially affecting system reliability and trust.
  • Availability: High
    CVE-2021-20587 can disrupt system operations, potentially causing complete denial of service (DoS).

Exploit Prediction Scoring System (EPSS)

The EPSS score estimates the probability that this vulnerability will be exploited in the near future.

EPSS Score: 1.894% (probability of exploit)

EPSS Percentile: 88.52% (lower percentile = lower relative risk)
This vulnerability is less risky than approximately 11.480000000000004% of others.

CVE-2021-20587 References

External References

CWE Common Weakness Enumeration

CWE-787

Vulnerable Configurations

  • cpe:2.3:a:mitsubishielectric:c_controller_module_setting_and_monitoring_tool:*:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:c_controller_module_setting_and_monitoring_tool:*:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:-:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:-:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:1.100e:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:1.100e:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:1.106k:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:cpu_module_logging_configuration_tool:1.106k:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:cw_configurator:-:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:cw_configurator:-:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:cw_configurator:1.010l:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:cw_configurator:1.010l:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:cw_configurator:1.011m:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:cw_configurator:1.011m:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:data_transfer:-:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:data_transfer:-:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:data_transfer:3.40s:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:data_transfer:3.40s:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:data_transfer:3.41t:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:data_transfer:3.41t:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:data_transfer:3.42u:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:data_transfer:3.42u:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:fr_configurator:*:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:fr_configurator:*:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:fr_configurator_sw3:*:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:fr_configurator_sw3:*:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:fr_configurator2:-:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:fr_configurator2:-:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:fr_configurator2:1.22y:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:fr_configurator2:1.22y:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:fr_configurator2:1.23z:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:fr_configurator2:1.23z:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gt_designer3:-:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gt_designer3:-:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gt_designer3:1.221f:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gt_designer3:1.221f:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gt_designer3:1.235v:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gt_designer3:1.235v:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gt_designer3:1.236w:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gt_designer3:1.236w:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gt_softgot1000:-:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gt_softgot1000:-:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gt_softgot1000:3.0:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gt_softgot1000:3.0:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gt_softgot1000:3.200j:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gt_softgot1000:3.200j:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gt_softgot1000:3.245f:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gt_softgot1000:3.245f:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gt_softgot2000:-:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gt_softgot2000:-:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gt_softgot2000:1.0:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gt_softgot2000:1.0:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gt_softgot2000:1.170c:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gt_softgot2000:1.170c:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gt_softgot2000:1.235v:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gt_softgot2000:1.235v:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gt_softgot2000:1.236w:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gt_softgot2000:1.236w:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gt_softgot2000:1.241b:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gt_softgot2000:1.241b:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gx_configurator-dp:-:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gx_configurator-dp:-:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gx_configurator-dp:7.14q:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gx_configurator-dp:7.14q:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gx_configurator-qp:*:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gx_configurator-qp:*:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gx_developer:-:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gx_developer:-:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gx_developer:8.504a:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gx_developer:8.504a:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gx_explorer:*:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gx_explorer:*:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gx_iec_developer:*:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gx_iec_developer:*:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gx_logviewer:-:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gx_logviewer:-:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gx_logviewer:1.100e:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gx_logviewer:1.100e:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gx_logviewer:1.106k:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gx_logviewer:1.106k:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gx_remoteservice-i:*:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gx_remoteservice-i:*:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gx_works2:-:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gx_works2:-:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gx_works2:1.11m:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gx_works2:1.11m:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gx_works2:1.590q:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gx_works2:1.590q:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gx_works2:1.595v:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gx_works2:1.595v:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gx_works2:1.597x:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gx_works2:1.597x:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gx_works3:-:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gx_works3:-:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gx_works3:1.060n:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gx_works3:1.060n:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gx_works3:1.063r:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gx_works3:1.063r:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gx_works3:1.065t:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gx_works3:1.065t:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:gx_works3:1.070y:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:gx_works3:1.070y:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:iq_monozukuri_andon:-:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:iq_monozukuri_andon:-:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:iq_monozukuri_process_remote_monitoring:-:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:iq_monozukuri_process_remote_monitoring:-:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:m_commdtm-hart:*:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:m_commdtm-hart:*:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:m_commdtm-io-link:*:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:m_commdtm-io-link:*:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:melfa-works:-:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:melfa-works:-:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:melfa-works:4.4:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:melfa-works:4.4:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:melsec_wincpu_setting_utility:*:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:melsec_wincpu_setting_utility:*:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:melsoft_em_software_development_kit:*:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:melsoft_em_software_development_kit:*:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:melsoft_navigator:-:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:melsoft_navigator:-:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:melsoft_navigator:1.04e:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:melsoft_navigator:1.04e:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:melsoft_navigator:2.62q:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:melsoft_navigator:2.62q:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:melsoft_navigator:2.70y:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:melsoft_navigator:2.70y:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:melsoft_navigator:2.74c:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:melsoft_navigator:2.74c:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:mh11_settingtool_version2:-:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:mh11_settingtool_version2:-:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:mh11_settingtool_version2:2.003d:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:mh11_settingtool_version2:2.003d:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:mt_works2:-:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:mt_works2:-:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:mt_works2:1.156n:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:mt_works2:1.156n:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:mt_works2:1.160s:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:mt_works2:1.160s:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:mt_works2:1.167z:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:mt_works2:1.167z:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:mx_component:-:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:mx_component:-:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:mx_component:4.00a:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:mx_component:4.00a:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:mx_component:4.20w:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:mx_component:4.20w:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:network_interface_board_cc-link:*:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:network_interface_board_cc-link:*:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:network_interface_board_cc_ie_control_utility:*:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:network_interface_board_cc_ie_control_utility:*:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:network_interface_board_cc_ie_field_utility:*:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:network_interface_board_cc_ie_field_utility:*:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:network_interface_board_mneth_utility:*:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:network_interface_board_mneth_utility:*:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:px_developer:-:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:px_developer:-:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:px_developer:1.53f:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:px_developer:1.53f:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:rt_toolbox2:-:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:rt_toolbox2:-:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:rt_toolbox2:3.73b:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:rt_toolbox2:3.73b:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:rt_toolbox3:-:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:rt_toolbox3:-:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:rt_toolbox3:1.60n:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:rt_toolbox3:1.60n:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:rt_toolbox3:1.70y:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:rt_toolbox3:1.70y:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:rt_toolbox3:1.80j:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:rt_toolbox3:1.80j:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:rt_toolbox3:1.82l:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:rt_toolbox3:1.82l:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:setting\/monitoring_tools_for_the_c_controller_module:*:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:setting\/monitoring_tools_for_the_c_controller_module:*:*:*:*:*:*:*:*
  • cpe:2.3:a:mitsubishielectric:slmp_data_collector:-:*:*:*:*:*:*:*
    cpe:2.3:a:mitsubishielectric:slmp_data_collector:-:*:*:*:*:*:*:*

Protect Your Infrastructure against CVE-2021-20587: Combat Critical CVE Threats

Stay updated with real-time CVE vulnerabilities and take action to secure your systems. Enhance your cybersecurity posture with the latest threat intelligence and mitigation techniques. Develop the skills necessary to defend against CVEs and secure critical infrastructures. Join the top cybersecurity professionals safeguarding today's infrastructures.

Other 5 Recently Published CVEs Vulnerabilities

  • CVE-2025-3284 – The User Registration & Membership – Custom Registration Form, Login Form, and User Profile plugin for WordPress is vulnerable to Cross-Site Reques...
  • CVE-2025-3278 – The UrbanGo Membership plugin for WordPress is vulnerable to privilege escalation in versions up to, and including, 1.0.4. This is due to the plugi...
  • CVE-2025-2010 – The JobWP – Job Board, Job Listing, Career Page and Recruitment Plugin plugin for WordPress is vulnerable to SQL Injection via the 'jobwp_upload_re...
  • CVE-2025-43903 – NSSCryptoSignBackend.cc in Poppler before 25.04.0 does not verify the adbe.pkcs7.sha1 signatures on documents, resulting in potential signature forgeries.
  • CVE-2025-3796 – A vulnerability classified as critical has been found in PHPGurukul Men Salon Management System 1.0. This affects an unknown part of the file /admi...