CVE-2019-6572 Vulnerability Analysis & Exploit Details

CVE-2019-6572
Vulnerability Scoring

9.1
/10
Critical Risk

As a catastrophic security flaw, CVE-2019-6572 has severe implications, demanding immediate intervention.

Attack Complexity Details

  • Attack Complexity: Low
    Exploits can be performed without significant complexity or special conditions.
  • Attack Vector: Network
    Vulnerability is exploitable over a network without physical access.
  • Privileges Required: None
    No privileges are required for exploitation.
  • Scope: Unchanged
    Exploit remains within the originally vulnerable component.
  • User Interaction: None
    No user interaction is necessary for exploitation.

CVE-2019-6572 Details

Status: Modified

Last updated: 🕟 21 Nov 2024, 04:46 UTC
Originally published on: 🕗 14 May 2019, 20:29 UTC

Time between publication and last update: 2017 days

CVSS Release: version 3

CVSS3 Source

nvd@nist.gov

CVSS3 Type

Primary

CVSS3 Vector

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N

CVE-2019-6572 Vulnerability Summary

CVE-2019-6572: A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.

Assessing the Risk of CVE-2019-6572

Access Complexity Graph

The exploitability of CVE-2019-6572 depends on two key factors: attack complexity (the level of effort required to execute an exploit) and privileges required (the access level an attacker needs).

Exploitability Analysis for CVE-2019-6572

With low attack complexity and no required privileges, CVE-2019-6572 is an easy target for cybercriminals. Organizations should prioritize immediate mitigation measures to prevent unauthorized access and data breaches.

Understanding AC and PR

A lower complexity and fewer privilege requirements make exploitation easier. Security teams should evaluate these aspects to determine the urgency of mitigation strategies, such as patch management and access control policies.

Attack Complexity (AC) measures the difficulty in executing an exploit. A high AC means that specific conditions must be met, making an attack more challenging, while a low AC means the vulnerability can be exploited with minimal effort.

Privileges Required (PR) determine the level of system access necessary for an attack. Vulnerabilities requiring no privileges are more accessible to attackers, whereas high privilege requirements limit exploitation to authorized users with elevated access.

CVSS Score Breakdown Chart

Above is the CVSS Sub-score Breakdown for CVE-2019-6572, illustrating how Base, Impact, and Exploitability factors combine to form the overall severity rating. A higher sub-score typically indicates a more severe or easier-to-exploit vulnerability.

CIA Impact Analysis

Below is the Impact Analysis for CVE-2019-6572, showing how Confidentiality, Integrity, and Availability might be affected if the vulnerability is exploited. Higher values usually signal greater potential damage.

  • Confidentiality: High
    Exploiting CVE-2019-6572 can result in unauthorized access to sensitive data, severely compromising data privacy.
  • Integrity: High
    CVE-2019-6572 could allow unauthorized modifications to data, potentially affecting system reliability and trust.
  • Availability: None
    CVE-2019-6572 does not impact system availability.

Exploit Prediction Scoring System (EPSS)

The EPSS score estimates the probability that this vulnerability will be exploited in the near future.

EPSS Score: 0.38% (probability of exploit)

EPSS Percentile: 73.2% (lower percentile = lower relative risk)
This vulnerability is less risky than approximately 26.799999999999997% of others.

CVE-2019-6572 References

External References

CWE Common Weakness Enumeration

CWE-798

CAPEC Common Attack Pattern Enumeration and Classification

  • Read Sensitive Constants Within an Executable CAPEC-191 An adversary engages in activities to discover any sensitive constants present within the compiled code of an executable. These constants may include literal ASCII strings within the file itself, or possibly strings hard-coded into particular routines that can be revealed by code refactoring methods including static and dynamic analysis.
  • Try Common or Default Usernames and Passwords CAPEC-70 An adversary may try certain common or default usernames and passwords to gain access into the system and perform unauthorized actions. An adversary may try an intelligent brute force using empty passwords, known vendor default credentials, as well as a dictionary of common usernames and passwords. Many vendor products come preconfigured with default (and thus well-known) usernames and passwords that should be deleted prior to usage in a production environment. It is a common mistake to forget to remove these default login credentials. Another problem is that users would pick very simple (common) passwords (e.g. "secret" or "password") that make it easier for the attacker to gain access to the system compared to using a brute force attack or even a dictionary attack using a full dictionary.

Vulnerable Configurations

  • cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:14.0:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:14.0:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:14.0:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:14.0:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:14.0:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:14.0:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:14.0:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:14.0:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:14.0:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:14.0:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:14.0:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:14.0:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:14.0:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:14.0:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*
  • cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):-:*:*:*:professional:*:*:*
    cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):-:*:*:*:professional:*:*:*
  • cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):10.0:*:*:*:*:*:*:*
    cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):10.0:*:*:*:*:*:*:*
  • cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):11.0:*:*:*:*:*:*:*
    cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):11.0:*:*:*:*:*:*:*
  • cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):12.0:*:*:*:*:*:*:*
    cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):12.0:*:*:*:*:*:*:*
  • cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):13.0:*:*:*:*:*:*:*
    cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):13.0:*:*:*:*:*:*:*
  • cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):13:sp1:*:*:professional:*:*:*
    cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):13:sp1:*:*:professional:*:*:*
  • cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):14:*:*:*:professional:*:*:*
    cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):14:*:*:*:professional:*:*:*
  • cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):14.0:*:*:*:basic:*:*:*
    cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):14.0:*:*:*:basic:*:*:*
  • cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):14.0:*:*:*:advanced:*:*:*
    cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):14.0:*:*:*:advanced:*:*:*
  • cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):14.0:*:*:*:comfort:*:*:*
    cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):14.0:*:*:*:comfort:*:*:*
  • cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):14.0:*:*:*:*:*:*:*
    cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):14.0:*:*:*:*:*:*:*
  • cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):15.0:*:*:*:*:*:*:*
    cpe:2.3:a:siemens:simatic_wincc_\(tia_portal\):15.0:*:*:*:*:*:*:*
  • cpe:2.3:a:siemens:simatic_wincc_runtime:-:*:*:*:advanced:*:*:*
    cpe:2.3:a:siemens:simatic_wincc_runtime:-:*:*:*:advanced:*:*:*
  • cpe:2.3:a:siemens:simatic_wincc_runtime:-:*:*:*:professional:*:*:*
    cpe:2.3:a:siemens:simatic_wincc_runtime:-:*:*:*:professional:*:*:*
  • cpe:2.3:a:siemens:simatic_wincc_runtime:13:-:*:*:professional:*:*:*
    cpe:2.3:a:siemens:simatic_wincc_runtime:13:-:*:*:professional:*:*:*
  • cpe:2.3:a:siemens:simatic_wincc_runtime:13:sp1:*:*:professional:*:*:*
    cpe:2.3:a:siemens:simatic_wincc_runtime:13:sp1:*:*:professional:*:*:*
  • cpe:2.3:a:siemens:simatic_wincc_runtime:13:sp1:update_2:*:professional:*:*:*
    cpe:2.3:a:siemens:simatic_wincc_runtime:13:sp1:update_2:*:professional:*:*:*
  • cpe:2.3:a:siemens:simatic_wincc_runtime:13:sp1:update_9:*:professional:*:*:*
    cpe:2.3:a:siemens:simatic_wincc_runtime:13:sp1:update_9:*:professional:*:*:*
  • cpe:2.3:a:siemens:simatic_wincc_runtime:14:*:*:*:professional:*:*:*
    cpe:2.3:a:siemens:simatic_wincc_runtime:14:*:*:*:professional:*:*:*
  • cpe:2.3:a:siemens:simatic_wincc_runtime:14:-:*:*:professional:*:*:*
    cpe:2.3:a:siemens:simatic_wincc_runtime:14:-:*:*:professional:*:*:*
  • cpe:2.3:a:siemens:simatic_wincc_runtime:14.0:*:*:*:advanced:*:*:*
    cpe:2.3:a:siemens:simatic_wincc_runtime:14.0:*:*:*:advanced:*:*:*
  • cpe:2.3:a:siemens:simatic_wincc_runtime:14.0:*:*:*:professional:*:*:*
    cpe:2.3:a:siemens:simatic_wincc_runtime:14.0:*:*:*:professional:*:*:*
  • cpe:2.3:a:siemens:simatic_wincc_runtime:14:sp1:*:*:professional:*:*:*
    cpe:2.3:a:siemens:simatic_wincc_runtime:14:sp1:*:*:professional:*:*:*
  • cpe:2.3:a:siemens:simatic_wincc_runtime:15:-:*:*:professional:*:*:*
    cpe:2.3:a:siemens:simatic_wincc_runtime:15:-:*:*:professional:*:*:*
  • cpe:2.3:o:siemens:simatic_hmi_tp_firmware:*:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:simatic_hmi_tp_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:simatic_hmi_tp:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:simatic_hmi_tp:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:simatic_hmi_mp_firmware:*:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:simatic_hmi_mp_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:simatic_hmi_mp:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:simatic_hmi_mp:-:*:*:*:*:*:*:*
  • cpe:2.3:o:siemens:simatic_hmi_op_firmware:*:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:simatic_hmi_op_firmware:*:*:*:*:*:*:*:*
  • cpe:2.3:h:siemens:simatic_hmi_op:-:*:*:*:*:*:*:*
    cpe:2.3:h:siemens:simatic_hmi_op:-:*:*:*:*:*:*:*

Protect Your Infrastructure against CVE-2019-6572: Combat Critical CVE Threats

Stay updated with real-time CVE vulnerabilities and take action to secure your systems. Enhance your cybersecurity posture with the latest threat intelligence and mitigation techniques. Develop the skills necessary to defend against CVEs and secure critical infrastructures. Join the top cybersecurity professionals safeguarding today's infrastructures.

Other 5 Recently Published CVEs Vulnerabilities

  • CVE-2025-3103 – The CLEVER - HTML5 Radio Player With History - Shoutcast and Icecast - Elementor Widget Addon plugin for WordPress is vulnerable to arbitrary file ...
  • CVE-2025-3275 – The Themesflat Addons For Elementor plugin for WordPress is vulnerable to Stored Cross-Site Scripting via the TF E Slider widget in all versions up...
  • CVE-2025-1457 – The Element Pack Addons for Elementor – Free Templates and Widgets for Your WordPress Websites plugin for WordPress is vulnerable to Stored Cross-S...
  • CVE-2025-1093 – The AIHub theme for WordPress is vulnerable to arbitrary file uploads due to missing file type validation in the generate_image function in all ver...
  • CVE-2025-3284 – The User Registration & Membership – Custom Registration Form, Login Form, and User Profile plugin for WordPress is vulnerable to Cross-Site Reques...